Agilent 16910A and 16911A Specifications and Characteristics  
State (Synchronous) Analysis Mode  
tWidth* [1]  
Option 250  
1.5 ns  
Option 500  
1.5 ns  
tSetup  
0.5 tWidth  
0.5 tWidth  
–3.2 ns to ꢀ3.2 ns  
80 ps typical  
250 Mb/s  
0.5 tWidth  
0.5 tWidth  
–3.2 ns to ꢀ3.2 ns  
80 ps typical  
500 Mb/s  
tHold  
tSample range [2]  
tSample adjustment resolution  
Maximum state data rate on each channel  
Maximum channels on a single time base  
and trigger [4]  
16910A: 510 – (number of clocks)  
16911A: 340 – (number of clocks)  
16910A: 510 – (number of clocks)  
16911A: 340 – (number of clocks)  
Memory depth [4]  
(Option 256 is included in base price)  
Option 256: 256 K samples  
Option 001: 1 M samples  
Option 004: 4 M samples  
Option 016: 16 M samples  
Option 032: 32 M samples  
Option 256: 256 K samples  
Option 001: 1 M samples  
Option 004: 4 M samples  
Option 016: 16 M samples  
Option 032: 32 M samples  
Number of independent analyzers [5]  
Number of clocks [6]  
2
1
4
1
Number of clock qualifiers [6]  
4
N/A  
2.0 ns  
Minimum time between active  
clock edges* [7]  
4.0 ns  
Minimum master to slave clock time  
Minimum slave to master clock time  
Minimum slave to slave clock time  
1 ns  
N/A  
N/A  
N/A  
1 ns  
4.0 ns  
*
Items marked with an asterisk (*) are specifications. All others are characteristics.  
Typical” represents the average or median value of the parameter based on measurements from a significant number of units.  
[1] Minimum eye width in system under test.  
[2] Sample positions are independently adjustable for each data channel input. A negative sample position causes the input to be synchronously sampled by that amount before  
each active clock edge. A positive sample position causes the input to be synchronously sampled by that amount after each active clock edge. A sampling position of zero  
causes the input to be synchronously sampled coincident with each clock edge.  
[3] Use of eye finder is recommended in 450 MHz and 500 Mb/s state mode.  
[4] In 250 Mb/s state mode, with all pods assigned, memory depth is half the maximum memory depth. With one pod pair (34 channels) unassigned, the memory depth is full. One  
pod pair (34 channels) must remain unassigned for time tags in 500 Mb/s state mode.  
[5] Independent analyzers may be either state or timing. When the 500 Mb/s state mode is selected, only one analyzer may be used.  
[6] In the 250 Mb/s state mode, the total number of clocks and qualifiers is 4. All clock and qualifier inputs must be on the master modules.  
[7] Tested with input signal Vh = ꢀ1.3 V, Vl = ꢀ0.7 V, threshold = ꢀ1.0 V, tr/tf = 180 ps 30 ps (10ꢁ, 90ꢁ).  
tWidth  
Individual  
Data Channel  
vHeight  
Data Eye  
vThreshold  
OV  
tSetup tHold  
Sampling Position  
Clock Channel  
tSample  
8

与16911A相关器件

型号 品牌 描述 获取价格 数据表
169127 ERNI MaxiBridge Standardkabelkonfektionen

获取价格

169128 ERNI MaxiBridge Standardkabelkonfektionen

获取价格

169129 ERNI MaxiBridge Standardkabelkonfektionen

获取价格

169130 ERNI MaxiBridge Standardkabelkonfektionen

获取价格

169131 ERNI MaxiBridge Standardkabelkonfektionen

获取价格

169132 ERNI MaxiBridge Standardkabelkonfektionen

获取价格