15B-ZPD Series
TEMPERATURE CHARACTERISTICS
TYPICAL CHARACTERISTICS
Parameter
Conditions
Min.
Typ.
Max.
Units
Temperature Derating Graph
Output voltage accuracy
Refer to recommended circuit
±1
±3
%
Over load protection
Output Short Circuit
Load regulation
Input voltage range
Input voltage range
120
130
150
%
Hiccup,automatics recovery
From 10% to 100% load
±0.5
±1
%
Trim
±10%V0
VDC
%/℃
%
Temperature drift (Vout)
Line regulation
0.02
Input voltage from low to high
Tested under 20MHz brand
25% load change
±0.2
75
±0.5
150
300
±5
Ripple&Noise
50
mV
Transient recovery time
Transient peak deviation
200
±3
us
±2
%
RECOMMENDED CIRCUIT
3.3V
5V
3.63
5.5
4.29
6.5
VDC
VDC
VDC
VDC
VDC
Output Graph
Over voltage protection
12V
15V
24V
13.2
16.5
26.4
15.6
19.5
31.2
Note:
1. All specifications are measured at TA=25°C, humidity<75%, nominal input voltage and rated output load
unless otherwise specified.
2. The CTRL control pin voltage is referenced to GND.
In order to obtain better performance for the DC/DC
models.it’s recommended that use input and output
filters as Fig.1 shown.
3. Typical efficiency value at nominal input voltage and full load.
4. Capacitor MAX load tested at nominal input voltage and constant resistive load.
5. Refer to the diagram of Output Voltage trim up/down for trim applications.
6. The products cannot be used in parallel and in plug and play.
L:12uH
C:100uF/100V
DERATING&EFFICIENCY CURVE
OUTPUT VOLTAGE TRIM
Requirement on output load
Output Graph
In order to ensure the product operate efficiently and reliably,in addition to a
max load(namely full load), a minimum load is specified for this kind of
DC/DC converter.Make sure the specified range of input voltage is not
exceeded,the minimum output load no less than 10% load.If the actual
load is less than the specified minimum load, the output ripple may increase
sharply while its efficiency and reliability will reduce greatly.If the actual
output power is very small,please add an appropriate resistor as extra
loading,or contact our company for other lower output power products.
Curve of Efficiency VS input Voltage 15B2424ZPD
Curve of Efficiency VS output load WRB2424YD-30W
No parallel connection or plug and play
http://www.microdc.cn Technical Enquiries-Email:tech@microdc.cn Tel:0086-20-86000646
Page 2 of 3