Power Line Filters
Single Stage
62-PPF/PQF/PRF Series
Features
Tested and found to be
IAW VDE 0565 Part 3
I
Low-cost plastic case
I
Compact design requires minimal real estate space
Circuit Diagrams
I
Suitable for products that must conform
to FCC and FTZ regulations
L1
I
I
Wide variety of circuit and filtering options
CX
CY
CY
62-PQF*
Series
Good filtering characteristics for both normal mode
and common mode
R
I
I
Epoxy molded for reliability
Operating temperature: -25°C to +85°C
(including temperature rise, see graph on page PF55)
L1
CY
CY
62-PPF*
Series
Applications
CX
R
I
Personal computers and peripherals
I
Digital equipment
I
Industrial equipment
I
Vending machines
CX
CY
CY
L1
L1
62-PRF*
Series
R
I
Office equipment
* Bleeder Resistor is available only for
62-P(Q/R/P)F-XXX-X-12
Specifications
Rated Voltage
Rated
Leakage Current
(Max.)
Capacitance
Inductance
(L1)
Temperature
Rise (Max.)
Model
(@ 50/60Hz)
Current
CY
CX
62-PQF-020-5-11
62-PQF-020-5-12
62-PPF-020-5-11
62-PPF-020-5-12
62-PQF-030-5-11
62-PQF-030-5-12
62-PPF-030-5-11
62-PPF-030-5-12
62-PQF-060-5-11
62-PQF-060-5-12
62-PPF-060-5-11
62-PPF-060-5-12
62-PRF-010-5-11
62-PRF-010-5-12
62-PRF-020-5-11
62-PRF-020-5-12
62-PRF-030-5-11
62-PRF-030-5-12
0.1uF
.22uF
0.1uF
.22uF
0.1uF
.22uF
0.1uF
.22uF
0.1uF
.22uF
0.1uF
.22uF
0.1uF
.22uF
0.1uF
.22uF
0.1uF
.22uF
2A
15mH
3A
6A
8mH
250VAC
0.50mA
3300pF
30°C
2.1mH
1A
2A
486uH
181uH
3A
97uH
Note: All types are designed to meet the requirement of UL 1283, CSA 22.2. VDE 0565-3
Test voltage: 1500VAC one minute, line to ground
Insulation resistance: 300 Mohm min. at 500VDC
Voltage drop: 1V max. (except 62-PRF-010-5-11) at rated current
62-PRF-010-5-11: 1.5V max. at rated current
Weight: 62-PPF & PQF Series: 2.11 ounces (60 grams)
62-PRF Series: 1.76 ounces (50 grams)
API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com
API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
PF54