11AA02E48/11AA02E64
TABLE 1-2:
AC CHARACTERISTICS
Electrical Characteristics:
AC CHARACTERISTICS
Industrial (I):
VCC = 2.5V to 5.5V
VCC = 1.8V to 2.5V
TA = -40°C to +85°C
TA = -20°C to +85°C
Param.
No.
Symbol
Characteristic
Min.
Max.
Units
Test Conditions
1
FBUS
Serial Bus
Frequency
10
100
kHz
2
3
TE
Bit Period
10
—
100
µs
UI
TIJIT
Input Edge Jitter
Tolerance
±0.06
Note 2
4
5
FDRIFT Serial Bus
Frequency Drift Rate
—
—
±0.50
±5
% per byte
Tolerance
FDEV
Serial Bus
% per command
Frequency Drift Limit
6
7
TOJIT
TR
Output Edge Jitter
—
—
±0.25
100
UI
ns
Note 2
SCIO Input Rise
Time (Note 1)
8
9
TF
SCIO Input Fall Time
(Note 1)
—
100
ns
TSTBY Standby Pulse Time
600
10
—
—
µs
µs
10
11
12
13
TSS
THDR
TSP
Start Header Setup
Time
Start Header Low
Pulse Time
5
—
µs
ns
Input Filter Spike
Suppression (SCIO)
—
—
50
Note 1
TWC
Write Cycle Time
(byte or page)
5
ms
ms
Write, WRSR commands
ERAL, SETAL commands
25°C, VCC = 5.5V (Note 3)
10
—
14
Endurance (per
page)
1M
cycles
Note 1: This parameter is periodically sampled and not 100% tested.
2: A Unit Interval (UI) is equal to 1-bit period (TE) at the current bus frequency.
3: This parameter is not tested but ensured by characterization. For endurance estimates in a specific
application, please consult the Total Endurance™ Model which can be obtained on Microchip’s website:
www.microchip.com.
TABLE 1-3:
AC TEST CONDITIONS
AC Waveform
VLO = 0.2V
VHI = VCC - 0.2V
CL = 100 pF
Timing Measurement Reference Level
Input
0.5 VCC
0.5 VCC
Output
2008-2016 Microchip Technology Inc.
DS20002122D-page 3