EFS50-0KF0A023A | EFS/EFM50
MOTOR FEEDBACK SYSTEMS ROTARY HIPERFACE DSL®
PIN assignment
Supply / Communication pin assignment
1
2 3 4
Integrated in the motor cable = J, K
PIN Signal
Explanation
1
not connected
2
3
4
+U /DSL+
Power supply/DSL-Data
S
GND/DSL– Ground connection/DSL-Data
not connected
Recommended outer diameter of stranded cable: 4 mm +0/–0.3 mm
Recommended mating connector: JST (GHR-04V-S)
Temperature sensor pin assignment
2
1
PIN Signal Explanation
1
2
T+
T–
Thermistor connection
Thermistor connection (Ground)
Recommended outer diameter of stranded cable: 2.2 mm ꢀ.1 mm
Recommended mating connector: Harwin M8ꢀ-899ꢀ2ꢀ5
Diagram
Electrical self-heating
Diagram 3
Typ. mechanical self-heating, kelvin (K)
8
7
6
5
4
3
2
1
0
20 40 60 80 100 120 140
Ambient temperature (C°)
-40 -20
0
Electrical self-heating
2017-06-07 19:23:08 | Online data sheet
Subject to change without notice
MOTOR FEEDBACK SYSTEMS | SICK
5