STR1-SASM03P5 | STR1
NON-CONTACT SAFETY SWITCHES
Ordering information
A
B
C
D
E
F
Type
STR1-SASM03P5
Part no.
1069562
Other models and accessories www.sick.com/STR1
Detailed technical data
Features
Sensor and actuator
System part
H
I
Transponder
Sensor principle
2
1
Number of safe outputs
Auxiliary contact (AUX)
Safe switch on distance Sao
Active front sensor surface 10 mm
Active side sensor surface 6 mm
J
25 mm
Safe switch off distance Sar
Active sensor surfaces
Actuation directions
Coding
K
L
3
5
Universally coded
Safety-related parameters
M
N
O
P
Q
R
S
T
SIL3 (IEC 61508), SILCL3 (EN 62061)
Category 4 (EN ISO 13849)
PL e (EN ISO 13849)
Safety integrity level
Category
Performance level
5,21 x 10-9 (EN ISO 13849)
PFHD (mean probability of a dangerous fail-
ure per hour)
20 years (EN ISO 13849)
Type 4 (EN ISO 14119)
TM (mission time)
Type
Low coding level (EN ISO 14119)
Actuator coding level
Safe state in the event of a fault
At least one safety-related semiconductor output (OSSD) is in the OFF state.
Interfaces
Cable, 5-wire
Connection type
Length of cable 3 m
Cable material PVC
2
SAFETY SWITCHES | SICK
Online data sheet | 2018-09-06 10:37:18
Subject to change without notice