DME4000-219 | DME4000
LONG RANGE DISTANCE SENSORS
Ordering information
A
B
C
D
E
F
Type
DME4000-219
Part no.
1042839
Other models and accessories www.sick.com/DME4000
Detailed technical data
Performance
0.15 m ... 130 m, on reflective tape "Diamond Grade"
Measuring range
Resolution
0.05 mm ... 5 mm
H
I
2 mm 1) 2)
± 5 mm
4 ms
Repeatability
Accuracy
Output time
Light source
Laser, red 3)
J
2 (EN 60825-1 / CDRH)
Laser class
130 mm (at 70 m)
270 mm (at 150 m)
360 mm (at 220 m)
Typ. light spot size (distance)
K
L
10 m/s
Max. movement speed
1)
On reflective tape "Diamond Grade"
2)
Statistical error 1 σ, environmental conditions constant, min. warm-up time 10 min.
3)
Average service life of 50,000 h at T = +25 °C.
A
M
N
O
P
Q
R
S
T
Interfaces
CANopen
CiA 301
Data interface
CANopen application layer
Mechanics/electronics
Supply voltage Vs
Ripple
DC 18 V ... 30 V, limit values
1)
< 5 Vpp
1.5 s 2)
Initialization time
Male connector, M12, 5-pin
Display
Connection type
Indication
1)
May not fall short of or exceed V tolerances.
S
2)
3)
After loss of reflector < 1 s at max. speed V
< 1 m/s.
max
Short-circuit protected, overload-protected. Max. 100 nF / 20 mH.
2
DISTANCE SENSORS | SICK
Online data sheet | 2016-03-17 13:18:11
Subject to change without notice