Tektronix Logic Analyzers – TLA7000 Series
™
Integrated View (iView ) capability
™
TLA mainframe configuration
requirements
GPIB-iView (Opt. 1C)
™
USB-iView (Opt. 2C)
Number of Tektronix oscilloscopes
that can be connected to a TLA
system
1
External oscilloscopes supported More than 100. For a complete listing of current supported oscilloscopes, please visit our website http://www.tektronix.com/iview.
TLA connections
USB, Trigger In, Trigger Out, Clock Out
Oscilloscope connections
™
GPIB-iView (Opt. 1C)
GPIB, Trigger In, Trigger Out, Clock In (when available)
USB Device Port, Trigger In, Trigger Out
™
USB-iView (Opt. 2C)
™
Setup
iView external oscilloscope wizard automates setup.
Data correlation
After oscilloscope acquisition is complete, the data is automatically transferred to the TLA and time correlated with the TLA
acquisition data.
™
Deskew
The oscilloscope and TLA data is automatically deskewed and time correlated when using the iView external oscilloscope cable.
™
GPIB-iView (Opt. 1C) External
2 m (6.6 ft.)
2 m (6 ft.)
oscilloscope cable length
™
USB-iView (Opt. 2C) External
oscilloscope cable length
Symbolic support
Number of symbols/ranges
Unlimited (limited only by amount of virtual memory available on TLA)
Object file formats supported
IEEE695, OMF 51, OMF 86, OMF 166, OMF 286, OMF 386, COFF, Elf/Dwarf 1 and 2, Elf/Stabs, TSF (If your software
development tools do not generate output in one of the above formats, TSF, or the Tektronix symbol file, a generic ASCII file
format is supported. The generic ASCII file format is documented in the TLA online help). If a format is not listed, please contact
your local Tektronix representative.
External instrumentation interface
System Trigger output
System Trigger input
External Signal output
External Signal input
Asserted whenever a system trigger occurs (TTL-compatible output, back-terminated into 50 Ω)
Forces a system trigger when asserted (adjustable threshold between 0.5 V and 1.5 V, edge sensitive, falling-edge latched)
Can be used to drive external circuitry from a module's trigger mechanism (TTL-compatible output, back-terminated into 50 Ω)
Can be used to provide an external signal to arm or trigger any or all modules (adjustable threshold between 0.5 V and 1.5 V, level
sensitive)
www.tektronix.com
5