030/031 AS
Vishay BCcomponents
www.vishay.com
Table 5
TEST PROCEDURES AND REQUIREMENTS
TEST
PROCEDURE
(quick reference)
REQUIREMENTS
NAME OF TEST
REFERENCE
Case Ø D x L = 4.5 mm x 10 mm to 10 mm x 25 mm
UR 6.3 V; C/C: + 15 %/- 30 %
UR > 6.3 V; C/C: 15 %
tan 1.3 x spec. limit
Z 2 x spec. limit
IEC 384-4/
T
amb = 85 °C; UR applied;
Endurance
EN130300
2000 h
subclause 4.13
IL spec. limit
UR 6.3 V; C/C: + 45 %/- 50 %
UR > 6.3 V; C/C: 45 %
tan 3 x spec. limit
CECC 30301
subclause 1.8.1
Tamb = 85 °C; UR and IR applied;
3000 h
Useful life
Z 3 x spec. limit
IL spec. limit
no short or open circuit
total failure percentage: 1 %
Tamb = 85 °C; no voltage applied;
C/C, tan , Z:
Shelf life
IEC 384-4/
500 h
for requirements
(storage at
EN130300
see “Endurance test” above
After test: UR to be applied for 30 min,
24 h to 48 h before measurement
high temperature)
subclause 4.17
IL 2 x spec. limit
Revision: 24-Apr-12