0.5T8E_1U Series
0.5W - Single Output DC-DC Converter - Fixed Input - Isolated & Unregulated
DC-DC Converter
0.5 Watt
The 0.5T8E_1U series is specially designed for applications where a group of polar
power supplies are isolated from the input power supply in a distributed power
supply system on a circuit board.
Small footprint
Industry standard pinout
Low temperature rise
Internal SMD construction
No external component
required
Miniature SMD package style
High efficiency up to 78%
1000VDC isolation
Temperature range:
-40°C ~ +85°C
These products apply to:
1) Where the voltage of the input power supply is fixed (voltage variation ≤ 10ꢀ)
2) Where isolation is necessary between input and output
(isolation voltage ≤1000VDC)
RoHS compliance
3) Where the regulation of the output voltage and the output ripple noise are not
demanding
Such as: digit circuit condition; normal low-frequency artificial circuit condition;
relay drive circuit condition, etc.
Common specifications
Short circuit protection:
Temperature rise at full load:
Cooling:
Output specifications
1 second
Item
Test condition
Min
Typ
5
Max
Units
ꢀ
25°C TYP (Ta = 25°C)
Free air convection
-40°C ~ +85°C
Output voltage
accuracy
Line regulation
Load regulation
For Vin change of 1ꢀ
1.2
15
ꢀ
Operation temperature range:
Storage temperature range:
Lead temperature
10ꢀ to 100ꢀ load
• 3.3V
• 5V
• 9V
• 12V
• 15V
-40°C ~ +100°C
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
15
9
7.5
7
300°C MAX, 1.5mm from case for 10 sec
< 95ꢀ
Storage humidity range:
Package material:
Epoxy Resin [UL94-V0]
>3,500,000 hours
1g
Transient response
setting time
50ꢀ load step change
350
µs
MTBF (MIL-HDBK-217F@25°C):
Weight:
Temperature drift
Ripple & Noise*
100ꢀ full load
0.03
100
ꢀ/°C
Dimensions:
12.7*7.6*6.25mm
20MHz Bandwidth
mVp-
p
Switching frequency Full load, nominal input
100
KHz
Input specifications
Item
Test condition
Capacitor
Min
Typ
Max
10
Units
ꢀ
* Ripple and noise tested with “parallel cable” method. See detailed operation
instructions at DC-DC Application Notes.
Voltage tolerance
Filter
Example:
0.5T8E_0505S1U
0.5 = 0.5Watt; T8 = SMT8; E = Series; 05 = 5Vin; 05 = 5Vout;
S = Single output; 1 = 1kVDC; U = Unregulated output
Isolation specifications
Item
Test condition
Min
Typ
Max
Units
VDC
Isolation voltage
1000
1000
Note:
1. Operation under minimum load will not damage the converter; However, they
may not meet all specification listed.
Isolation resistance
Test at 500VDC
MΩ
2. Max. Capacitive Load tested at input voltage range and full load.
3. All specifications measured at Ta = 25°C, humidity < 75ꢀ, nominal input voltage
and rated output load unless otherwise specified.
4. In this datasheet, all the test methods of indications are based on our corpo-
rate standards.
Page 1 of 3
0.5T8E_1U – Rev. 2017-1.1
Specifications subject to change without notice.
GAPTEC-Electronic GmbH & Co. KG