15
ZWS
ZWS15 Specifications
ꢀ
MODEL
ZWS15-3
ZWS15-5
ZWS15-12
ZWS15-15
ZWS15-24
ITEMS/UNITS
Voltage Range
Frequency
(*3)
V
AC85 - 265 or DC110 - 330
(*3) Hz
47 - 440
Input Efficiency (typ)
(*2)
%
A
63
71
Current (100/200VAC)(typ)
0.45 / 0.23
Inrush Current (100/200VAC)(typ)
Nominal Voltage
A
15 / 30 at, Ta=25℃, cold start
VDC
A
3.3
5
12
15
24
Minimum Current
0
Maximum Current
A
3
1.25
1
0.65
0.78
15.6
18.72
96
Maximum Peak Current
Maximum Power
(*1)
(*1)
A
3.6
1.5
1.2
W
W
9.9
15.0
Maximum Peak Power
11.88
18.0
Output Maximum Line Regulation (*4)(*10) mV
Maximum Load Regulation(*5)(*10) mV
20
40
48
60
96
120
180
150
Temperature Coefficient
(*6) mV
60
140
280
200
200
Maximum Ripple & Noise (0 to +60℃)(*10) mVp-p
Maximum Ripple & Noise (-10 to 0℃)(*10) mVp-p
120
160
150
180
Hold-up Time (100VAC)(typ)
Voltage Adjustable Range
Over Current Protection
Over Voltage Protection
Parallel Operation
(*2) ms
17 at 100VAC, 15W, Ta=25℃
±10%
>125%
(*7)
(*8)
>140%
Function
-
Possible
Series Operation
(*9)
Operating Temperature
Storage Temperature
Operating Humidity
(*11)
℃
℃
%RH
%RH
-10 to +50 : 100%, +60 : 70%
-30 to +85
30 - 90
Environment Storage Humidity
10 - 95
Vibration
Shock
10-55Hz amplitude (sweep 1min) less than 19.6m/s² X, Y, Z 1h each
Less than 196.1m/s²
Cooling
Convection cooling
Input - FG : 2kVAC (20mA), Input - Output : 3kVAC (20mA)
Output - FG : 500VAC (100mA) for 1min
Withstand Voltage
Isolation
Isolation Resistance
More than 100MΩ at 25℃ and 70%RH Output - FG 500VDC
Safety Standards
Approved by UL60950-1, CSA C22.2 No.60950-1. EN60950-1. Built to meet DENAN.
Standards
EMI
Built to meet EN55022-B, FCC-ClassB, VCCI-B
Weight (typ)
Mechanical
g
140
Size (W x H x D)
mm
50 x 21 x 125
(*1) Operating time at peak output is less than 10 seconds. (Duty=0.35)
(*2) At 100VAC and maximum output current, Ta=25℃.
●Recommended EMC Filter
(*3) For cases where conformance to various safety specs (UL, CSA) are required, to be described as 100 -
240VAC, 50/60Hz on name plate.
(*4) From 85 - 265VAC and constant load.
(*5) From Min load - Full load (maximum power) and constant input voltage.
(*6) From -10 ~ +50℃ constant input voltage and load.
RSEL-2001W
(*7) Current limiting with automatic recovery.
Avoid to operate over load or dead short for 30 seconds.
Please refer to "TDK-Lambda
EMC Filters" catalog.
(*8) Over voltage clamping by zener diode.
(*9) Refer to instruction manual.
(*10) Please refer to Fig A for measurement of line & load regulation and ripple voltage.
(*11) At standard mounting method, Fig B.
Measurement point
for Vripple
L
C2
C1
CN2
COMPONENT SIDE
Fig.B
PCB
L:150mmAWG#22
C1:Elec.Cap 100uF
C2:Film Cap 1uF
Measurement point for Vo,
Line/Load Regulation.
Bandwidth of scope:100MHz
Fig.A
ZWS
・All specifications are subject to change without notice.
A-408