ZWS5
ZWS5 Specifications
ꢀ
MODEL
ZWS5-3
ZWS5-5
ZWS5-12
ZWS5-15
ZWS5-24
ITEMS/UNITS
Voltage Range
Frequency
(*3)
V
AC85 - 265 or DC110 - 330
(*3) Hz
47 - 440
Input Efficiency (typ)
(*2)
%
A
62
67
5
68
70
24
Current (100/200VAC)(typ)
0.14 / 0.07
Inrush Current (100/200VAC)(typ)
Nominal Voltage
A
15 / 30 at Ta=25℃, cold start
V
3.3
12
15
Minimum Current
A
0
Maximum Current
A
1
0.42
0.34
0.41
5.1
0.22
0.27
5.28
6.336
96
Maximum Peak Current
Maximum Power
(*1)
(*1)
A
1.2
0.51
W
W
3.3
5.0
6.0
5.04
Maximum Peak Power
3.96
6.048
6.12
60
Output Maximum Line Regulation (*4)(*10) mV
Maximum Load Regulation(*5)(*10) mV
20
40
48
96
120
180
150
Temperature Coefficient
(*6) mV
60
140
280
200
200
Maximum Ripple & Noise (0 to +60℃)(*10) mVp-p
Maximum Ripple & Noise (-10 to 0℃)(*10) mVp-p
120
160
150
180
Hold-up Time (100VAC)(typ)
Voltage Adjustable Range
Over Current Protection
Over Voltage Protection
Parallel Operation
(*2) ms
17 at 5W, Ta=25℃
+/-10%
(*7)
(*8)
>125%
>140%
Function
-
Possible
Series Operation
(*9)
Operating Temperature
Storage Temperature
Operating Humidity
(*11)
℃
℃
%RH
%RH
-10 to +50: 100%, +60: 70%
-30 to +85
30 - 90
Environment Storage Humidity
10 - 95
Vibration
Shock
10-55Hz (sweep 1min) less than 19.6m/s² X, Y, Z 1h each
Less than 196.1m/s²
Cooling
Convection cooling
Withstand Voltage
Isolation
Input - FG: 2kVAC (20mA), Input - Output: 3kVAC (20mA), Output - FG: 500VAC (100mA) for 1min
Isolation Resistance
More than 100MΩ at 25℃ and 70%RH Output - FG 500VDC
Safety Standards
Approved by UL60950-1,CSA C22.2 No.60950-1,EN60950-1, Built to meet DENAN
Standards
EMI
Built to meet EN55022-B, FCC-ClassB, VCCI-B
Weight (typ)
Mechanical
g
120
Size (W x H x D)
mm
45 x 21 x 98
(*1) Operating time at peak output is less than 10 seconds. (Duty=0.35)
●Recommended EMC Filter
(*2) At 100VAC and maximum output current, Ta=25℃.
(*3) For cases where conformance to various safety specs (UL,CSA) are required, to
be described as 100 - 240VAC, 50/60Hz on name plate.
(*4) From 85 - 265VAC and constant load.
(*5) From min load - full load (maximum power) and constant input voltage.
(*6) From -10 to +50℃ constant input voltage and load.
(*7) Current limiting with automatic recovery.
RSEL-20R5W
Please refer to "TDK-Lambda
EMC Filters" catalog.
Avoid to operate over load or dead short for 30 seconds.
(*8) Over voltage clamping by zener diode.
(*9) Refer to instruction manual.
(*10) Please refer to Fig A for measurement of line & load regulation and ripple voltage.
(*11) At standard mounting method, Fig B.
Measurement point
for Vripple
L
C2
C1
CN2
COMPONENT SIDE
Fig.B
PCB
L:150mmAWG#22
C1:Elec.Cap 100uF
C2:Film Cap 0.1uF
Measurement point for Vo,
Line/Load Regulation.
Bandwidth of scope:100MHz
Fig.A
ZWS
・All specifications are subject to change without notice.
A-404