ZTT4.91MG
Ceramic Resonator
6. PHYSICAL AND ENVIRONMENTAL CHARACTERISTICS
Performance
Requirements
No.
Item
Condition of Test
Subject the resonator at +40℃±2℃ and
90%~95% R.H. for 500h, resonator shall be
measured after being placed in natural
conditions for 1h.
It shall fulfill the
specifications in
Table 1.
6.1
Humidity
High
Subject the resonator to +85℃±5℃ for It shall fulfill the
500h, resonator shall be measured after being specifications in
6.2
6.3
Temperature
Exposure
Low
Temperature
Exposure
placed in natural conditions for 1h.
Table 1.
Subject the resonator to –25℃±5℃ for It shall fulfill the
500h, resonator shall be measured after being specifications in
placed in natural conditions for 1h.
Table 1.
Subject the resonator to -25℃ for 30 min.
followed by a high temperature of +85℃ for It shall fulfill the
30 min. Cycling shall be repeated 5 times. specifications in
Resonator shall be measured after being Table 1.
placed in natural conditions for 1h.
Temperature
Cycling
6.4
6.5
6.6
6.7
Subject the resonator to vibration for 2h each
in x y and z axis with the amplitude of It shall fulfill the
1.5mm, the frequency shall be varied specifications in
uniformly between the limits of 10Hz~55Hz Table 1.
and then resonator shall be measured.
Vibration
No
visible
Resonator shall be measured after 3 times' damage and it
random dropping from the height of 100cm shall fulfill the
Mechanical
Shock
on concrete floor.
specifications in
Table 1.
Lead terminals are immersed up to 2 mm
Resistance to
Soldering
Heat
from resonator’s body in soldering bath of It shall fulfill the
+260℃±5℃ for 5s±1s and then resonator specifications in
shall be measured after being placed in Table 1.
natural conditions for 1h
More than 95%
of the terminal
Lead terminals are immersed up to 2mm from
surface of the
resonator’s body in soldering bath of +235℃
resonator shall be
6.8
Solderability
±5℃ for 2s±0.5s.
covered
with
fresh solder.
http://www.luguang.cn