Related Products
Type
Part Number
Description
Z+ Low Voltage Series Datasheet
19” Rack Housing
Dual/Triple Housing
Blanking Panel
Blanking Panel
Cable
DB9 Cable
DB9 Cable
Cable
Z+ Low Voltage
Z-NL100
Z-NL200
Z-BP
Z+ 10V to 100V Programmable Power Supplies
Accepts four 105mm width units or six 70mm width units
Accepts two 105mm case units or three 70mm case units
70mm Blanking Panel For 19” Rack
105mm Blanking Panel For 19” Rack
Serial Link Cable (One is included with each power supply)
Communication Cable RS-485
Z-WBP
Z-RJ45
Z-485-9
Z-232-9
Z-U
Communication Cable RS-232
2m North American AC cord (Included with U option)
Specifications
Model
Z160
Z320
Z650
Input
Input Voltage Range
Input Frequency
Input Current (100/200Vac)
Vac
Hz
A
85 - 265
47 - 63
200W: 2.76 / 1.37, 400W: 5.25 / 2.57, 600W: 10 / 4.9, 800W: 10.3 / 5.1
Inrush Current at 200Vac (typ) (Cold Start)
Leakage Current (220Vac)
Power Factor (100/200Vac)
Harmonic Compliance
A
mA
-
-
200W: <30, 400W: <25, 600W: <25, 800W: <30
<1.2
>0.99 / 0.98
Meets IEC61000-3-2 Class A
Hold Up Time (typ)
Efficiency
Conducted & Radiated EMI
Immunity
Insulation Class
ms
200W: 15, 400W: 15, 600W: 15, 800W: 10
See Model Selector Table
IEC/EN61326-1, -B radiated, -A conducted, designed to meet EN55032/EN55024
See IEC61000 reports on website
Class I
-
-
-
-
-
Safety Certifications and Markings
Output
IEC/UL/CSA/EN61010-1,60950, CE Mark and UKCA Mark
Output Voltage and Current Adjustment
Load Regulation (CV Mode)
Line Regulation (CV Mode)
Transient Response Recovery Time(1)
Load Regulation (CC Mode)
Line Regulation (CC Mode)
Ripple & Noise (CC or CV Mode)
Temperature Coefficient (CV Mode)
Temperature Stability (CV Mode)
Warm-up Drift (CV Mode)
Temperature Coefficient (CC Mode)
Temperature Stability (CC Mode)
Load Regulation Thermal Drift (CC Mode)
Warm-up Drift (CC Mode
Up Programming Resp Time (CV Mode)
(10-90% or 90-10% of Vmax)(2)
Down Programming Resp Time (CV Mode)
Full Load (10-90% or 90-10% of Vmax)(2)
Minimum Load
-
%
%
ms
%
%
-
ppm/°C
%
%
ppm/°C
%
%
See Model Selector Table
0.01 of rated voltage over 0 - 100% load change
0.01 of rated voltage over a 85 - 132 or 170 - 265Vac line change
2
0.09 of rated current over 0 - 100% Vout change
0.15 of rated output current
0.02 of rated current over a 85 - 132 or 170 - 265Vac line change
See Model Selector Table
30 (following 30 minute warm up)
0.02 of rated voltage over 8 hours following 30 minute warm up time
<0.05 of rated output voltage (after 30 min warm up period)
100 (following 30 minute warm up)
0.05 of rated current over 8 hours following 30 minute warm up time
< 0.05 of rated current over 30 minutes after load change
±0.1 of rated output current over 30 minutes following power on
%
ms
ms
110
180
170
270
170
270
-
-
V
-
No minimum load required
User programmable, can be set to foldback mode
Shut down. User programmable
Overcurrent Protection
Overvoltage Protection
Overtemperature Protection
Remote Sense Compensation (per wire)
Remote On/Off
User selectable - latched or non-latching
5
By applied voltage or dry contact relay (user selectable logic)
Open Collector, Low on fail
V
DC Good
Communication
-
-
RS232, RS485 & USB standard, IEEE488 (GPIB) & LAN optional
Green LEDs: FINE, MENU, PREV, PROT, REM, OUTPUT, CV, CC
Red LED: PROT (OVP, UVP, OTP, FOLD, AC FAIL).
4 digits. Accuracy 0.5% of rated voltage or current ±1 count
Up to 6 units
Indicators
-
Display
Parallel Operation
-
2
Z+ High Voltage Series