Z+ Series
Specifications (See website for detailed specifications)
Model
Z10
Z20
Z36
Z60
Z100
Load Regulation
Line Regulation
Recovery Time
Temperature Coefficient
Temperature Stability
Warm up Drift
Up programming response time (10-90% or 90-10% of Vmax)
Down programming resp time (CV) (10-90% or 90-10% of Vmax) Full load
Down programming resp time (CV) (90-10% of Vmax) Zeroload
CV
CV
CV
CV
CV
CV
CV
2mV + 0.01% of rated voltage over 0 - 100% load change
2mV + 0.01% of rated voltage over a 85 - 132 or 170 - 265VAC line change
1ms
30ppm/°C following 30 minute warm up
0.02% of rated voltage over 8 hours following 30 minute warm up time
<0.05% of rated voltage + 2mV of rated output voltage
(1)
(2)
15ms
10ms
30ms
30ms
30ms
30ms
50ms
50ms
50ms
50ms
190ms
200ms
250ms
310ms
900ms
Load Regulation
Load Regulation thermal drift
Line Regulation
Temperature Coefficient
Temperature Stability
Warm up Drift
CC
CC
CC
CC
CC
CC
5mA + 0.01% of rated current over 0 - 100% Vout change
< 0.05% of rated current over 30 minutes after load change
2mA + 0.01% of rated current over a 85 - 132 or 170 - 265VAC line change
100ppm/°C of rated current after 30 minute warm up time
0.05% of rated current over 8 hours following 30 minute warm up time
<±0.1% of rated current
(2)
Vout & Iout programming & readback resolution
Vout & Iout programming & readback accuracy
Voltage & Current Programming
Voltage & Current Monitoring
Overvoltage Shutdown (user programmable)
Overtemperature Protection
Display - Voltage
Digitally
Digitally
Analog
Analog
< 0.012% of rated voltage/current
< 0.05% of rated voltage, < 0.1% of rated current
By either Voltage (0-5V or 0-10V) or Resistance (0-5k or 0-10k)
0-5V or 0-10V Voltage (user selectable), ±1% accuracy
V
-
-
-
0.5 - 12
1 - 24
2 - 40
5 - 66
5 - 110
User selectable - latched or non-latching
4 digits. Accuracy 0.5% of rated voltage or current ±1 count
By applied voltage or dry contact relay (user selectable logic)
Open Collector, Low on fail
Remote On/Off
Output Good
-
Remote Sense Compensation (per wire)
Communication Interface
Series Operation
Parallel Operation
Input Voltage / Frequency
Inrush Current
V
-
-
-
-
-
1
1
2
3
5
RS232, RS485 & USB standard, IEEE488 (GPIB) & LAN optional
Up to two identical units (with external diodes)
Up to six units in master-slave configuration
85-265VAC, 47-63Hz
(3)
< 25A
Hold Up Time (Typical)
Power Factor Correction
Operating Temperature
Storage Temperature
Humidity (non condensing)
Cooling
ms
-
°C
°C
16ms
Complies with EN61000-3-2 Class A (0.99 typ)
0 - 50°C
-20 to +85°C
%RH
Operating: 10 - 90%RH, Storage 10 - 95%RH
Internal temperature controlled fan
I/P to GND 2kVAC, I/P to O/P 3kVAC, O/P to GND 1380VDC 1 min
>100M at 25°C & 70%RH
-
-
-
-
-
-
-
-
Withstand Voltage
Insulation Resistance
Vibration (non operating)
Shock
Safety Agency Certifications
Immunity
Conducted & Radiated EMI
Size (H x W x D) (Excluding handles and busbars) mm
Weight
Warranty
IEC60068-2-64
<20G, half sine, 11ms. IEC60068-2-27
UL61010-1, EN61010-1, IEC61010 (Designed to meet UL/EN60950-1)
IEC61326 (Designed to meet EN55022 / EN55024)
EN55022-B, FCC part 15-B, VCCI-B
Standard body 83 x 70 x 350mm; Wide Body 83 x 105 x 350mm
Standard body 1.9kg; Wide Body 2.4kg
Five Years
kg
yrs
Notes:
For Additional Information, please visit
us.tdk-lambda.com/lp/products/zplus-series.htm
(1) Recovery to within 0.5% of rated voltage after a load
change of 10-90% (Output current 10-100% of Imax)
(2) Over 30 minute warm up time after power on
(3) Derate for 85-100 VAC; Z10-72-U (66A), Z20-40-U
(36A), Z36-24-U (20A), Z60-14-U (12.5A), Z100-8-U
(7.5A)