Pre-amplified/5V Excitation/Absolute
XFPM,XFAM Data sheet
Features
Applications
Industrial instrumentation
Medical device
Barometer, Altimeter
Altitude compensation
.
.
.
.
.
.
.
.
Two accuracy ranks, 1.5 FS and 2.5 FS available
Volt level output
On-chip amplification and temperature compensations
Pre-calibration of offset voltage and span
Part number for ordering
XFAM - 115KP A S R H
No mark : 2.5 FS
Accuracy
H
:
1.5 FS(Contact us about availability)
Terminal leads direction (See Outline Diagram)
No mark :
Rated pressure (Pa)
Model
XFPM
XFAM
R :
Pressure type
A : Absolute
Terminal leads configuration
No mark : DIP(XFPM)
S : Surface mount package(XFAM)
Pressure type
Absolute pressure
XFPM
XFAM
Model
Package configuration
Dual-In-line-Package (DIP)
Surface mount package
XFAM-115KPASR
Measurable pressure range (kPa)
15 115
Part number for ordering
XFPM-115KPAR
XFPM-115KPA
Specifications
Model/Rated pressure
115KPA
Unit
Recommended operating conditions
Pressure type
Rated pressure
Measurable pressure range
Pressure media
Absolute pressure
115
15 115
Non-corrosive gas only
.
kPa abs
.
kPa abs
Excitation voltage
5
0.25
VDC
VDC
Absolute maximum rating
Maximum load pressure
Maximum excitation voltage
Operating temperature
Storage temperature
Operating humidity
Twice of rated pressure
8
40 125
40 125
30 80 (No dew condensation)
RH
mA
Electric performances/characteristics (Excitation voltage Vcc=5.0V constant, Ambient temperature Ta=25
)
Current consumption
Output impedance
Source current
less than 10
less than 10
less than 0.2
mA
Sink current
less than 2
mA
Mechanical response time
Full scale span voltage
Offset voltage
Full scale span voltage
Accuracy
2 (For the reference)
4.5
0.2 0.1125, 0.2 0.0675(H)
4.7 0.1125, 4.7 0.0675(H)
2.5, 1.5(H)
msec
V
V
V
FS/0 85
Note ; Excluding input voltage error.
Please consult us available liquid pressure media when you chose the H models.
1