5秒后页面跳转
WJF-AC3-V/Q PDF预览

WJF-AC3-V/Q

更新时间: 2024-01-22 05:46:58
品牌 Logo 应用领域
爱模 - MSYSTEM /
页数 文件大小 规格书
4页 112K
描述
Dual Output Plug-in Signal Conditioners W-UNIT

WJF-AC3-V/Q 数据手册

 浏览型号WJF-AC3-V/Q的Datasheet PDF文件第2页浏览型号WJF-AC3-V/Q的Datasheet PDF文件第3页浏览型号WJF-AC3-V/Q的Datasheet PDF文件第4页 
MODEL: WJF  
Dual Output Plug-in Signal Conditioners W-UNIT  
[1] INPUT  
Current  
A: 4 – 20 mA DC (Input resistance 100 Ω)  
Voltage  
2-input MATH FUNCTION MODULE  
(field-programmable)  
6: 1 – 5 V DC (Input resistance 1 MΩ min.)  
Functions & Features  
• Providing temperature or pressure compensation for a gas  
flow, and other arithmetic operations  
• Microprocessor based  
[2] OUTPUT 1  
Current  
• Equation and parameters  
A: 4 – 20 mA DC (Load resistance 600 Ω max.)  
B: 2 – 10 mA DC (Load resistance 1200 Ω max.)  
C: 1 – 5 mA DC (Load resistance 2400 Ω max.)  
D: 0 – 20 mA DC (Load resistance 600 Ω max.)  
E: 0 – 16 mA DC (Load resistance 750 Ω max.)  
F: 0 – 10 mA DC (Load resistance 1200 Ω max.)  
G: 0 – 1 mA DC (Load resistance 12 kΩ max.)  
Z: Specify current (See OUTPUT SPECIFICATIONS)  
Voltage  
selectable on site via hand-held programmer PU-2x  
• Loop testing  
• Isolation up to 2000 V AC  
• High-density mounting  
Typical Applications  
• Various flowmeters  
• Adding two flows  
• Ratio calculation  
1: 0 – 10 mV DC (Load resistance 10 kΩ min.)  
2: 0 – 100 mV DC (Load resistance 100 kΩ min.)  
3: 0 – 1 V DC (Load resistance 1000 Ω min.)  
4: 0 – 10 V DC (Load resistance 10 kΩ min.)  
5: 0 – 5 V DC (Load resistance 5000 Ω min.)  
6: 1 – 5 V DC (Load resistance 5000 Ω min.)  
4W: -10 – +10 V DC (Load resistance 10 kΩ min.)  
5W: -5 – +5 V DC (Load resistance 5000 Ω min.)  
0: Specify voltage (See OUTPUT SPECIFICATIONS)  
• Calculating average temperature  
50  
(1.97)  
80  
(3.15)  
136  
(5.35)  
[3] OUTPUT 2  
mm (inch)  
Current  
A: 4 – 20 mA DC (Load resistance 350 Ω max.)  
B: 2 – 10 mA DC (Load resistance 700 Ω max.)  
C: 1 – 5 mA DC (Load resistance 1400 Ω max.)  
D: 0 – 20 mA DC (Load resistance 350 Ω max.)  
E: 0 – 16 mA DC(Load resistance 430 Ω max.)  
F: 0 – 10 mA DC (Load resistance 700 Ω max.)  
G: 0 – 1 mA DC (Load resistance 7000 Ω max.)  
Z: Specify current (See OUTPUT SPECIFICATIONS)  
Voltage  
MODEL: WJF–[1][2][3]–[4][5]  
ORDERING INFORMATION  
• Code number: WJF-[1][2][3]-[4][5]  
Specify a code from below for each of [1] through [5].  
(e.g. WJF-6AA-B/3/Q)  
• Special output ranges (For codes Z & 0)  
• Parameters  
Same range availability as Output 1  
Use Ordering Information Sheet (No. ESU-1980) to specify  
parameters. Default setting will be used if not otherwise  
specified.  
(K0  
= 1, K  
1
= 1, K  
2
= 1, A  
0
= 0 %, A  
1
= 0 %, A = 0 %)  
2
• Specify the specification for option code /Q  
(e.g. /C01/S01)  
Note: When the user requires a current and a voltage  
output, specify the current to be the Output 1 which allows  
a greater load.  
WJF SPECIFICATIONS  
ES-2280 Rev.10 Page 1/4  
http://www.m-system.co.jp/  

与WJF-AC3-V/Q相关器件

型号 品牌 获取价格 描述 数据表
WJF-ACA-B MSYSTEM

获取价格

Dual Output Plug-in Signal Conditioners W-UNIT
WJF-ACA-B/2 MSYSTEM

获取价格

Dual Output Plug-in Signal Conditioners W-UNIT
WJF-ACA-B/3 MSYSTEM

获取价格

Dual Output Plug-in Signal Conditioners W-UNIT
WJF-ACA-B/4 MSYSTEM

获取价格

Dual Output Plug-in Signal Conditioners W-UNIT
WJF-ACA-B/5 MSYSTEM

获取价格

Dual Output Plug-in Signal Conditioners W-UNIT
WJF-ACA-B/Q MSYSTEM

获取价格

Dual Output Plug-in Signal Conditioners W-UNIT
WJF-ACA-C MSYSTEM

获取价格

Dual Output Plug-in Signal Conditioners W-UNIT
WJF-ACA-C/2 MSYSTEM

获取价格

Dual Output Plug-in Signal Conditioners W-UNIT
WJF-ACA-C/3 MSYSTEM

获取价格

Dual Output Plug-in Signal Conditioners W-UNIT
WJF-ACA-C/4 MSYSTEM

获取价格

Dual Output Plug-in Signal Conditioners W-UNIT