描述
Optical Amplifier Platform,1724-Type Eribium-Doped Fiber Amplifier(W Series)

W1724CDDAD 数据手册

 浏览型号W1724CDDAD的Datasheet PDF文件第1页浏览型号W1724CDDAD的Datasheet PDF文件第3页浏览型号W1724CDDAD的Datasheet PDF文件第4页浏览型号W1724CDDAD的Datasheet PDF文件第5页浏览型号W1724CDDAD的Datasheet PDF文件第6页浏览型号W1724CDDAD的Datasheet PDF文件第7页 
Data Sheet, Rev. 1  
September 2001  
Optical Amplifier Platform, 1724-Type  
Erbium-Doped Fiber Amplifier (W Series)  
Standard Features  
TTL-Compatible Alarm Outputs  
The standard W1724-Type EDFA incorporates the opti-  
cal architecture illustrated in Figure 1. The standard  
features include:  
Loss of Input Power Alarm  
If the input power is more than 2 dBm below the mini-  
mum PIN, the loss of input power alarm (pin 19) will  
activate (TTL-logic 1).  
Exceptional performance benefits with the integral  
microcontroller, which precisely controls the gain to  
maintain a flat spectral response over various input  
powers.  
Loss of Output Power Alarm  
Single 5 V power supply eliminates the need for dual  
voltage source circuits.  
If the output power decreases by more than 2 dB from  
its beginning-of-life value, the loss of output power  
alarm (pin 8) will activate (TTL-logic 1).  
DB-25 electrical connector allows for easy electrical  
connectivity.  
Optical input tap enables input monitoring and con-  
trol.  
Pumps Temperature Alarm  
If the laser temperature for the pump(s) exceeds 35 °C,  
the pump temperature alarm (pin 10) will activate (TTL-  
logic 1).  
SC/PC optical connector.  
Low power dissipation.  
Alarms:  
— Loss of input power alarm.  
Pumps Bias Alarm  
— Loss of output power alarm.  
— Pump bias alarm (>95% of EOL value).  
— Pump temperature alarm (TL > 35 °C).  
— EDFA temperature alarm (TC > 60 °C).  
If the bias current for the pump(s) exceeds 95% of its  
EOL value, the pump bias alarm (pin 9) will activate  
(TTL-logic 1).  
Advanced microprocessor design requires minimal  
engineering for a shelf-level product.  
EDFA Temperature Alarm  
Standard mechanical outline includes metric screws  
and fiber outputs (using SC/PC optical connectors)  
at 180 degrees relative to a DB25 electrical connec-  
tor. The standard product does not include a heat  
sink.  
If the case temperature exceeds 60 °C, then the  
EDFA temperature alarm (pin 7) will activate (TTL-  
logic 1).  
Optional Features  
Other feature and package options for the W1724-Type  
EDFA include:  
Alternative optical connectors  
Integral heat sink  
2
2
Agere Systems Inc.  

与W1724CDDAD相关器件

型号 品牌 描述 获取价格 数据表
W172DIP-1 ETC 172DIP PCB Mount Miniature Reed Relay

获取价格

W172DIP-141 SCHNEIDER Electromechanical Relay, SPDT, 5.5VDC (Coil), 290mW (Coil), 0.25A (Contact), 100VDC (Conta

获取价格

W172DIP-145 ETC 172DIP PCB Mount Miniature Reed Relay

获取价格

W172DIP-146 SCHNEIDER Electromechanical Relay, SPDT, 26.4VDC (Coil), 290mW (Coil), 0.25A (Contact), 100VDC (Cont

获取价格

W172DIP-147 ETC RELAY REED DIL 5VDC

获取价格

W172DIP-149 ETC RELAY REED DIL 12VDC

获取价格