1 of 5
page
date
11/19/2007
PART NUMBER: VPF-S200-XXRI series
DESCRIPTION: switching power supply
features
·power factor correction
·power good signal
·short circuit protection
·over load, voltage, temperature protection
·approved to UL/cUL, TUV, CE with CB
scheme
·N+1 parallel redundancy
·extended temperature range: -40 ~ +75°C
available
4
MODEL
preset
voltage
(V)
max. output
power / current (A)
with force air
1, 2, 3
5, 6
output
(V)
ripple & noise
(Vp-p)
5
convection
regulation
1ꢀ
VPF-S200-03RI
VPF-S200-05RI
VPF-S200-12RI
VPF-S200-24RI
VPF-S200-36RI
VPF-S200-48RI
3 - 4 V
5 - 6 V
3.3 V
5 V
30 A
200W
200W
200W
200W
200W
22 A
1ꢀ
1ꢀ
1ꢀ
1ꢀ
1ꢀ
1ꢀ
22 A
1ꢀ
12 - 18 V
24 - 30 V
32 - 46 V
48 - 56 V
12 V
24V
150W
150W
150W
150W
1ꢀ
1ꢀ
36 V
48 V
1ꢀ
1ꢀ
notes:
1. customer must specify output voltage on PO
2. output is fully isolated
3. output voltage is measured at output power connector
4. maximum 200 W with 18. cfm forced ventilation
5. 1% minimum load is required to maintain the ripple and regulation
6. ripple and noise are measured from 10 KHz to 20 MHz at output terminals with a 0.1 µF ceramic capacitor and a 22 µF capacitor in parallel.
th