VKS-8262 Klystron
CPI Microwave Power Products (MPP) offers the
VKS-8262 series of klystrons for use in particle
accelerators for scientific, medical, and industrial
applications. These klystrons provide up to 7.5
MW peak at 2.856 or 2.9985 GHz at various rf pulse
lengths and duty. Versions are available with up to
36 kW of average output power at 2.856 GHz and 72
kW at 2.9985 GHz.
FꢀATꢁꢂꢀꢃ
•ꢀDiodeꢀElectronꢀGun
ꢀ •ꢀWaterꢀCooled
ꢀ •ꢀElectromagnetꢀFocusing
ꢀ •ꢀWR-284ꢀWaveguideꢀOutput
ꢀ •ꢀThousandsꢀinꢀService
ꢀ •ꢀLongꢀLife
ꢀ •ꢀProvenꢀReliability
VKS-8262 KꢀꢁSꢂꢃꢄꢅS Aꢂ 2.856 GHz
Peak
ꢄutput
Power
(MW)
5.5
Peak
Drive
Power
Bandwidth
Peak
Beam
Voltage*
(kV)
Peak
Beam
Current*
(A)
ꢃF Pulse
ꢀength
(µsec)
Product ꢂype
(-3 dB)
Duty
(MHz)
VKS-8262S
VKS-8262J
VKS-8262M
VKS-8262F
VKS-8262P1
200
200
80
5
5
5
4
4
127
92
5.8
10
0.00104
0.00314
0.004
4.5
125
92
3
110
72
10
5
200
200
125
91
16.3
16.3
0.0072
0.009
5
125
92
VKS-8262 KꢀꢁSꢂꢃꢄꢅS Aꢂ 2.9985 GHz
Peak
Peak
Drive
Power
Bandwidth
Peak
Beam
Voltage*
(kV)
160
Peak
Beam
Current*
(A)
ꢃF Pulse
ꢀength
(µsec)
Product ꢂype
ꢄutput
(-3 dB)
Duty
Power
(MHz)
(MW)
VKS-8262G
VKS-8262E
VKS-8262D
VKS-8262HS
VKS-8262K
VKS-8262ꢅ
7.5
6
120
200
200
80
5
5
5
5
4
4
110
4.5
5.0
5.8
10
0.001
0.001
0.001
0.004
0.0072
0.0144
135
109
5.5
3
130
105
110
72
5
200
200
125
91
16.3
16.3
5
125
92
* These are the maximum allowable operating values according to the Product Specification.
Actual operating values are typically lower.
The values listed above represent specified limits for the product and are subject to change. The data should be used for basic
information only. Formal, controlled specifications may be obtained from CPI for use in equipment zdesign.
For information on this and other CPI products, visit our website at: www.cpii.com,
or contact: CPI MPP Division, 607 Hansen Way, Palo Alto, CA 94303
t e l e p h o n e : 1(800) 414-8823. f a x : (650) 856-0705 | e m a il : marketing@cpii.com