MODULE SPECIFIC OPERATING SPECIFICATIONS (CONT.)
24 Vout, 50 W (e.g. V24C24C50BL)
Parameter
Efficiency
Min
87
Typ
88.6
80
Max
Unit
%
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwith
25°C; recycle input voltage to restart (>100 ms off)
No load
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
100
29.1
3
mV
27.1
28.1
2
Volts
Watts
%
±0.02
±0.2
2.08
2.81
2.81
No load to full load; nominal input
0
Amps
Amps
Amps
Current limit
2.12
1.45
2.39
2.39
Output voltage 95% of nominal
Output voltage <250mV
Short circuit current
28 Vout, 100 W (e.g. V24C28C100BL)
Parameter
Efficiency
Min
88
Typ
89
Max
Unit
%
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20 MHz bandwith
25°C; recycle input voltage to restart (>100 ms off)
No load
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
85
107
33.9
5
mV
31.5
32.7
3.3
Volts
Watts
%
±0.02
±0.2
3.57
5
No load to full load; nominal input
0
Amps
Amps
Amps
Current limit
3.64
0.5
4.12
4.12
Output voltage 95% of nominal
Output voltage <250 mV
Short circuit current
5
28 Vout, 50 W (e.g. V24C28C50BL)
Parameter
Efficiency
Min
87.5
Typ
89
Max
Unit
%
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwith
25°C; recycle input voltage to restart (>100 ms off)
No load
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
80
100
33.9
2.7
mV
31.5
32.7
1.8
Volts
Watts
%
±0.02
±0.2
1.78
2.42
2.42
No load to full load; nominal input
0
Amps
Amps
Amps
Current limit
1.82
1.25
2.06
2.06
Output voltage 95% of nominal
Output voltage <250mV
Short circuit current
36 Vout, 100 W (e.g. V24C36C100BL)
Parameter
Efficiency
Min
86
Typ
87.1
32
Max
Unit
%
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwith
25°C; recycle input voltage to restart (>100 ms off)
No load
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
40
mV
40.4
41.9
3.7
43.4
4.3
Volts
Watts
%
±0.02
±0.2
2.78
3.76
3.76
No load to full load; nominal input
0
Amps
Amps
Amps
Current limit
2.83
1.94
3.2
3.2
Output voltage 95% of nominal
Output voltage <250 mV
Short circuit current
36 Vout, 50 W (e.g. V24C36C50BL)
Parameter
Efficiency
Min
84
Typ
84.9
27
Max
Unit
%
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwith
25°C; recycle input voltage to restart (>100 ms off)
No load
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
34
mV
40.4
41.9
1.8
43.4
2.3
Volts
Watts
%
±0.02
±0.2
1.39
1.88
1.88
No load to full load; nominal input
0
Amps
Amps
Amps
Current limit
1.41
0.97
1.6
1.6
Output voltage 95% of nominal
Output voltage <250 mV
Short circuit current
Vicor Corp.
Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
24V Micro Family
Rev. 4.7
Page 6 of 13
Set your site on VICOR at vicorpower.com