Specifications
General Specifications (See vicorpower.com for model specific data sheets)
PARAMETER
MIN
TYP
MAX
UNITS
NOTES
Input Characteristics
Undervoltage turn-on
24V
48V
300V
375V
24V
48V
300V
375V
17.5
34.9
174.6
242.5
15.3
17.9
35.7
178.2
247.5
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
Undervoltage turn-off
14.74
29.4
147.4
204.7
36.3
30.5
152.8
212.2
37.8
Overvoltage turn-off/on 24V
39.6
82.5
48V
300V
375V
75.7
78.8
Not Included
446.3
429.2
467.5
Output Characteristics
Line regulation
Temperature regulation
Power sharing accuracy
0.02
0.002
2
0.20
0.005
5
%
%/°C
%
Low line to high line; full load
Over operating temperature range
10 to 100% of full load
For trimming below 90% of
nominal, a minimum load
may be required.
Programming range
10
110
% Vnom
Current limit
Short circuit current
115
115
% Iout
% Iout
Output voltage 95% of nominal
Output voltage < 250mV
Isolation Characteristics
Complies with reinforced
insulation requirements
Complies with basic
insulation requirements
Complies with operational
insulation requirements
Isolation voltage (in to out)
3000
1550
500
Vrms
Vrms
Isolation voltage (in to base)
Isolation voltage (out to base)
Isolation resistance (in to out)
Vrms
10
Megohms
RATING
UNIT
NOTES
Thermal Characteristics
Operating temperature (H-grade)
Storage temperature (H-grade)
Operating temperature (M-grade)
Storage temperature (M-grade)
Temperature limiting (typical)
-40 to +100
-55 to +125
-55 to +100
-65 to +125
115
°C
°C
°C
°C
°C
Baseplate
Baseplate
Environmental Stress Screening
See page 30 for details
Control Functions - PC Pin
+In
PC
Module Enable/Disable. The module may
be disabled by pulling PC below 2.3V with
respect to the –Input. This may be done
with an open collector transistor, relay, or
optocoupler. Multiple converters may be
disabled with a single transistor or relay
either directly or via “OR’ing” diodes.
See Figure 1.
PR
–In
Disable
Disable = PC <2.3V
Figure 1 – Module enable/disable
Input Undervoltage
Input Overvoltage
Overtemperature
Module Faults
+In
PC
+Out
Auto
Restart
SW1
Module Alarm.The module contains
“watchdog” circuitry which monitors input
voltage, operating temperature, and internal
operating parameters. In the event that any
of these parameters are outside of their
allowable operating range, the module will
shut down and PC will go low. PC will
periodically go high and the module will
check to see if the fault (as an example,
overtemperature) has cleared. If the fault
has not been cleared, PC will go low again
and the cycle will restart. The SC pin will
go low in the event of a fault and return to
its normal state after the fault has been
cleared. See Figures 2 and 3.
+S
SC
–S
2-20ms typ.
50Ω
f
(V )
IN
SW1, 2,
&
3
SW2
SW3
1K
shown in
PR
"Fault" position
5.7Vdc
(0-3mA)
–In
1.23
Vdc
–Out
6K
Figure 2 – PC/SC module alarm logic
Fault
PC
40µs typ.
5.7V
1.23V
2-20ms typ.
SC
Figure 3 – PC/SC module alarm timing
9