MODULE FAMILY ELECTRICAL CHARACTERISTICS (CONT.)
MODULE CONTROL SPECIFICATIONS
Parameter
Min
Typ
Max
Unit
Notes
PRIMARY SIDE (PC = Primary Control; PR = Parallel)
PC bias voltage
current limit
5.50
1.5
5.75
2.1
6.00
3.0
Vdc
mA
PC current = 1.0 mA
PC voltage = 5.5 V
PC module disable
PC module enable delay
PC module alarm
2.3
2.6
4
2.9
7
Vdc
ms
Must be able to sink ≥4 mA. See Fig. 1
0.5
1.1
6.1
Vavg
MΩ
UV, OT, module fault. See Figs. 2 and 4
See Fig. 2
PC resistance
0.9
5.7
1.0
5.9
PR emitter amplitude
PR emitter current
PR receiver impedance
PR receiver threshold
PR drive capability
Volts
mA
PR load >30 Ω, <30 pF
150
375
2.4
500
2.5
625
2.6
12
Ω
25°C
Volts
modules
Minimum pulse width: 20 ns
Without PR buffer amplifier
SECONDARY SIDE (SC = Secondary Control)
SC bandgap voltage
SC resistance
1.21
990
1.23
1000
0.033
1.25
Vdc
Ω
Referenced to –Sense
1010
SC capacitance
µF
SC module alarm
0
Vdc
With open trim; referenced to –Sense. See Fig. 6
MODULE GENERAL SPECIFICATIONS
Parameter
Min
Typ
Max
Unit
Notes
Remote sense (total drop)
0.5
Vdc
0.25 V per leg (senses must be closed)
Isolation test voltage
in to out
3000
1500
500
Vrms
Vrms
Vrms
Complies with reinforced insulation requirements
Complies with basic insulation requirements
Complies with operational insulation requirements
in to base
out to base
Isolation resistance (in to out)
10
MΩ
3.9
4.0
ounces
(grams)
Weight
(110.6)
(113.4)
Temperature limiting
Agency approvals
100
115
°C
See Figs. 2 and 4
UL60950-1, EN60950-1, CSA60950-1, IEC60950-1.
With appropriate fuse in series with the +Input
cURus, TÜV, CE
Note:
Specifications are subject to change without notice.
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
110V Mini Family
Rev. 2.0
Page 3 of 13
Set your site on VICOR at www.vicorpower.com