Ordering information
AC-DC Power Supplies PCB Mount Type
TUH S
3
F
05
5
TUHS3
1
2
3
4
1Series name
2Single output
3Output wattage
4Universal Input
5Output voltage
R
ClassⅡ
*Avoid short circuit between +BC and -BC. It may cause the failure of inside components.
*To use TUHS, external components are required. Refer to the instruction manual for details.
MODEL
TUHS3F05
3.00
TUHS3F12
TUHS3F15
3.00
TUHS3F24
3.12
MAX OUTPUT WATTAGE[W]
DC OUTPUT
3.00
5V 0.6A
12V 0.25A
15V 0.2A
24V 0.13A
SPECIFICATIONS
MODEL
TUHS3F05
TUHS3F12
TUHS3F15
TUHS3F24
VOLTAGE[V]
AC85 - 264 1fDC120 - 370
ACIN 100V 0.08typ (Io=100%)
CURRENT[A]
ACIN 200V 0.05typ (Io=100%)
50/60 (47 - 63)
INPUT
FREQUENCY[Hz]
EFFICIENCY[%]
ACIN 100V 79typ
81typ
79typ
81typ
79typ
81typ
79typ
ACIN 200V 78typ
INRUSH CURRENT
VOLTAGE[V]
Limited by external components
5
12
15
24
CURRENT[A]
0.6
0.25
0.2
0.13
LINE REGULATION[mV]
20max
48max
60max
120max
160max
480max
200max
560max
240max
360max
60max
14.25 - 15.75
96max
LOAD REGULATION[mV] 40max
100max
160max
480max
200max
560max
180max
270max
48max
150max
200max
580max
240max
660max
360max
480max
96max
*1
30 to 100% Load
120max
400max
160max
480max
RIPPLE[mVp-p]
0 to 30% Load
*1
*1
AC85V - 240V
OUTPUT
30 to 100% Load
RIPPLE
NOISE[mVp-p]
0 to 30% Load
*1
AC85V - 240V
0 to +85C 100max
-40 to +85C 150max
TEMPERATURE
REGULATION[mV]
*
2
DRIFT[mV]
20max
OUTPUT VOLTAGE SETTING[V] 4.90 - 5.30
OVERCURRENT PROTECTION
11.40 - 12.60
23.00 - 25.00
Works over 105% of rating and recover automatically
13.20 - 19.20
PROTECTION CIRCUIT
AND OTHERS
OVERVOLTAGE PROTECTION[V] 5.50 - 8.00
16.50 - 24.00
26.40 - 38.40
ISOLATION
INPUT-OUTPUT
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (20 15C)
OPERATING TEMP.,HUMID.AND ALTITUDE -40 to +85C, 20 - 95%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000 feet) max
STORAGE TEMP.,HUMID.AND ALTITUDE
VIBRATION
-40 to +100C, 20 - 95%RH (Non condensing), 9,000m (30,000 feet) max
ENVIRONMENT
2
10 - 55Hz, 49.0m/s (5G), 3minutes period, 60minutes each along X, Y and Z axis
2
IMPACT
196.1m/s (20G), 11ms, once each along X, Y and Z axis
AGENCY APPROVALS
CONDUCTED NOISE
UL60950-1, C-UL (CSA60950-1), EN60950-1
SAFETY
AND NOISE
REGULATIONS
*
3
Complies with FCC-B,VCCI-B,CISPR-B,EN55022-B
HARMONIC ATTENUATOR Complies with IEC61000-3-2 (Class A) (Not built-in to active filter)
CASE SIZE/WEIGHT
COOLING METHOD
28.7X12.7X17.5mm[1.13X0.50X0.69 inches] (WXHXD) / 15g max
OTHERS
Convection / Forced air
*1 Refer to instruction manual for measuring method of electric characteristics.
*2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated value.
*3 Do not ground secondly circuit, in case of a standard adapted.
*
Measured with 18μF capasitor as Cbc.