ꢀ ꢁ ꢂ ꢃ ꢄꢅ ꢆ ꢇꢈ ꢈꢉ ꢀ ꢁ ꢂꢃ ꢄ ꢅ ꢃ ꢇꢈ ꢈ ꢉ ꢀꢁ ꢂ ꢃ ꢄ ꢅ ꢊ ꢇꢈ ꢈꢉ ꢀ ꢁꢂꢃ ꢄ ꢅ ꢋ ꢇꢈ ꢈ ꢉ ꢀ ꢁꢂꢃ ꢄ ꢅ ꢄ ꢇꢈ ꢈ
ꢁ ꢌꢍꢎ ꢏꢂꢂ ꢍꢌ ꢂ ꢐꢁ ꢏꢌꢑ ꢒ ꢂꢍ ꢌꢓ ꢎꢒ ꢌ ꢎꢐꢒ ꢀ ꢂ
ꢔ
SLVS165E – APRIL 1998 – REVISED DECEMBER 2002
†
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage, V
(see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 V
DD
RESET, RESET, MR, WDI (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –0.3 V to (V
Maximum low output current, I
Maximum high output current, I
Input clamp current range, I (V < 0 or V > V )
Output clamp current range, I
Continuous total power dissipation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . See Dissipation Rating Table
+ 0.3 V)
DD
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 mA
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –5 mA
OL
OH
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±10 mA
(V < 0 or V > V ) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±10 mA
IK
OK
I
I
DD
O
O
DD
Operating free-air temperature range, T
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –40°C to 85°C
A
Storage temperature range, T
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –65°C to 150°C
stg
Soldering temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 260°C
†
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTE 1: All voltage values are with respect to GND.
DISSIPATION RATING TABLE
OPERATING FACTOR
T
≤ 25°C
T
A
= 70°C
T = 85°C
A
POWER RATING
A
PACKAGE
POWER RATING
ABOVE T = 25°C
POWER RATING
A
DBV
437 mW
3.5 mW/°C
280 mW
227 mW
recommended operating conditions
MIN
1.1
MAX
UNIT
V
Supply voltage, V
DD
5.5
Input voltage, V
0
V
DD
+ 0.3
V
I
High-level input voltage at MR and WDI, V
IH
0.7 × V
V
DD
Low-level input voltage, V
IL
0.3 × V
100
V
DD
Input transition rise and fall rate at MR or WDI, ∆t/∆V
Operating free-air temperature range, T
ns/V
°C
–40
85
A
4