Temperature measurement
Probe
TP-203A-CF-H1141-L100
■
■
■
Pt-100 probe acc. to DIN EN 60751
Vibration and shock-resistant
Connectable to TS, TTM, IM34, BL20,
BL67
■
■
Max. temperature connector: 90 °C
4-wire connection technology
Wiring Diagram
Type designation
TP-203A-CF-H1141-L100
9910402
Ident-No.
General description
Resistance thermometers are used for the de-
tection and monitoring of temperatures to opti-
mize and control a process.
Temperature range
Measuring range
Temperature operating range
Accuracy
-50…500 °C
-58…932 °F
Typical applications are in machine and plant
construction as well as in the process industry.
0.15 °C + 0.002 ∙|t| (-30 …350 °C)
0.4 K/mW bei 0°C
Self-heating
Measuring element
Response time
Pt-100 probe, DIN EN 60751, class A
t 0.5 = 1.5 s / t 0.9 = 6.0 s in water at 0.2 m/s
100 mm
The core element of the temperature probe is
a temperature-dependent resistor.
Immersion depth (L)
Protection type and class
IP67
Ambient conditions
Ambient temperature
Storage temperature
-40…+85 °C
-40…+85 °C
Housing
Housing material
Sensor material
Process connection
Stainless steel, 1.4404 (316L)
Stainless steel, 1.4404 (316L)
For compression fittings, thermowell or direct mount-
ing
Electrical connection
Pressure resistance
Connector, M12 × 1
100 bar
Reference conditions acc. to IEC 61298-1
Temperature
15…+25 °C
Atmospheric pressure
Humidity
860…1060 hPa abs.
45…75 % rel.
24 VDC
Auxiliary power
MTTF
2283 years acc. to SN 29500 (Ed. 99) 20 °C
1 / 2
TURCK Inc. ñ 3000 Campus Drive Minneapolis, MN 55441-2656 ñ Phone: 763-553-7300 ñ Application Support: 1-800-544-7769 ñ Fax 763-553-0708 ñ www.turck.com