描述
AC-DC Power Supplies

THF120LS48 数据手册

 浏览型号THF120LS48的Datasheet PDF文件第2页浏览型号THF120LS48的Datasheet PDF文件第3页浏览型号THF120LS48的Datasheet PDF文件第4页 
45-480 Watts  
THF Series  
xppower.com  
Wide Adjustment Range  
Rugged for Industrial Use  
High Efficiency  
Overvoltage Protection  
Overcurrent Protection  
Overtemperature Protection  
Lightweight Design  
Specification  
Input  
General  
Input Voltage  
• 90-264 VAC except:  
Efficiency  
Isolation  
• 72-89% (see tables)  
90-132/176-264 VAC switch-selectable  
(THF120 and THF480LSxx models) and  
180-264 VAC (THF480PS models)  
• 3000 VAC Input to Output  
1500 VAC Input to Ground  
500 VAC Output to Ground  
Input Frequency  
Input Current  
• 47-63 Hz  
Switching Frequency  
• 100 kHz typical 45 & 240 W models  
70 kHz typical 480 W models  
50 kHz typical 75 & 120 W models  
• 0.5 A at 230 VAC 45 W models,  
0.8 A at 230 VAC 75 W models,  
1.4 A at 230 VAC 120 W models,  
1.8 A at 230 VAC 240 W models,  
4.0 A at 230 VAC 480 W models  
Environmental  
Operating Temperature • See derating curves  
Inrush Current  
Power Factor  
• 60 A max  
Operating Humidity  
Storage Temperature  
Vibration  
• 90% RH, non-condensing  
• -20 ˚C to +85 ˚C  
• All units EN61000-3-2 compliant,  
0.95 THF240, 0.70 THF480  
• 2 G, 10 Hz to 500 kHz, 10 min/cycle for 60  
minutes each axis  
Earth Leakage Current • <1.0 mA max 45 and 75 W models,  
<3.5 mA max 120, 240 & 480 W models  
at 240 VAC  
EMC & Safety  
Output  
Emissions  
• EN55022/55011, Class B conducted  
and radiated, EN61000-3-2, 3  
Output Voltage  
• See tables  
• ±10%  
Voltage Flicker  
ESD Immunity  
Radiated Immunity  
EFT/Burst  
• EN61000-3-3  
Output Voltage Trim  
Initial Set Accuracy  
Start Up Delay  
• EN61000-4-2, level 3 air, Perf Criteria B  
• EN61000-4-3, 10 V/m, Perf Criteria B  
• EN61000-4-4, level 3, Perf Criteria B  
• EN61000-4-5, level 3, Perf Criteria B  
• EN61000-4-6, 10 V rms, Perf Criteria B  
±2% max  
• 800 ms max 45 and 240 W models,  
1000 ms 75 W models,  
500 ms 120 W models,  
Surge  
1200 ms 480 W models  
Conducted Immunity  
Safety Approvals  
Start Up Rise Time  
Hold Up Time  
• 60 ms max 45 & 75 W models,  
70 ms max 120 W models,  
40 ms max 240 W & 480 W models  
• EN60950, UL508,  
(UL60950 on 120, 240 & 480 W models)  
• 50 ms at 230 VAC 45 & 75 W models,  
30 ms at 230 VAC 120 W models,  
20 ms at 230 VAC max 240 W models,  
16 ms at 230 VAC max 480 W models  
Line Regulation  
• ±1.0% max 45 W models,  
±0.5% 75, 120, 240 & 480 W models  
Load Regulation  
Ripple & Noise  
• ±0.5% max, ±1% max 45 W models  
• See tables  
Overvoltage Protection • 115-135%  
Overload Protection  
• 105-150%, constant current with auto  
recovery  
Temperature  
Coefficient  
• 0.03% /˚C  
1

与THF120LS48相关器件

型号 品牌 获取价格 描述 数据表
THF1210D1001FT FH

获取价格

薄膜片式固定电阻器
THF1210D1201FT FH

获取价格

薄膜片式固定电阻器
THF1210D1202FT FH

获取价格

薄膜片式固定电阻器
THF1210D2001FT FH

获取价格

薄膜片式固定电阻器
THF1210D3301FT FH

获取价格

薄膜片式固定电阻器
THF1210D3900FT FH

获取价格

薄膜片式固定电阻器
THF1210D5101FT FH

获取价格

薄膜片式固定电阻器
THF1210D5601FT FH

获取价格

薄膜片式固定电阻器
THF1210E1000DT FH

获取价格

薄膜片式固定电阻器
THF1210E1000FT FH

获取价格

薄膜片式固定电阻器