350W Single Output Switching Power Supply
SE-350 series
Features :
AC input range selectable by switch
Protections: Short circuit / Overload / Over voltage/
Over temperature
Forced air cooling by built-in DC fan
Withstand 300vac surge input for 5 second
Built-in cooling Fan ON-OFF control
Built-in constant current limiting circuit
100% full load burn-in test
LED indicator for power on
Fixed switching frequency at 90KHz
Low cost,high reliability
2 years warranty
SPECIFICATION
MODEL
SE-350-3.3
SE-350-5
SE-350-7.5
SE-350-12
SE-350-36
SE-350-48
SE-350-15
SE-350-24
SE-350-27
7.5V
DC VOLTAGE
3.3V
5V
60A
12V
15V
36V
48V
27V
24V
46A
RATED CURRENT
CURRENT RANGE
RATED POWER
60A
29A
23.2A
9.7A
7.3A
13A
14.6A
0 ~ 46A
345W
150mVp-p
6 ~ 9V
2.0%
0 ~ 60A
198W
0 ~ 60A
0 ~ 29A
348W
0 ~ 23.2A
348W
0 ~ 9.7A
349.2W
240mVp-p
32~40V
1.0%
0 ~ 7.3A
350.4W
240mVp-p
41 ~ 56V
1.0%
0 ~ 13A
351W
200mVp-p
26 ~ 32V
1.0%
0 ~ 14.6A
350.4W
150mVp-p
20 ~ 26.4V
1.0%
300W
RIPPLE & NOISE (max.) Note.2 150mVp-p
150mVp-p
150mVp-p
10 ~ 13.5V
1.5%
150mVp-p
13.5 ~ 18V
1.0%
OUTPUT
VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE Note.3
LINE REGULATION
2.97 ~ 3.7V 4.5 ~ 5.6V
+3%,-4.5%
0.5%
3.0%
0.5%
2.0%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
2.0%
0.5%
LOAD REGULATION
SETUP, RISE TIME
2.5%
1.0%
0.5%
0.5%
0.5%
0.5%
1000ms, 50ms/230VAC
1000ms,50ms/115VAC at full load
HOLD UP TIME (Typ.)
20ms/230VAC 16ms/115VAC at full load
90 ~ 132VAC / 180 ~ 264VAC by switch
47 ~ 63Hz
VOLTAGE RANGE Note.4
FREQUENCY RANGE
EFFICIENCY (Typ.)
254 ~ 370VDC
87.5%
83%
87.5%
74%
78%
4A/230VAC
60A/230VAC
80%
84%
87%
88%
INPUT
7A/115VAC
40A/115VAC
<3.5mA / 240VAC
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
105 ~ 135% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
18 ~ 21V
9.4 ~ 11.25V 13.8 ~ 16.2V 27.6 ~ 32.4V 33.7 ~ 39.2V
Protection type :Shut down O/P voltage, re-power on to recover
85 (3.3~7.5V); 80 (12V); 75 (15~48V) (TSW1) Detect on case
OVER LOAD
41.4~46.8V
57.6 ~ 67.2V
5.75 ~ 7.5V
3.8 ~ 4.6V
PROTECTION
OVER VOLTAGE
5
5
5
OVER TEMPERATURE
Protection type : Shut down O/P voltage, recovers automatically after temperature goes down
RTH2 50 FAN ON, 45 FAN OFF (3.3 ~ 7.5V)
RTH2 55 FAN ON, 50 FAN OFF (12 ~ 48V)
-20 ~ +60 (Refer to output load derating curve)
20 ~ 90% RH non-condensing
FAN ON/OFF CONTROL(Typ.)
FUNCTION
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
-20 ~ +85 , 10 ~ 95% RH
ENVIRONMENT
0.03%/ (0 ~ 50
10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
UL60950-1 approved
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC / 25 / 70% RH
SAFETY
MTBF
234.3K hrs min. MIL-HDBK-217F (25
215*115*50mm (L*W*H)
)
OTHERS
NOTE
DIMENSION
PACKING
1.07Kg; 12pcs/13.5Kg/0.92CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Please connect positive pole of input voltage with mark N of terminal block, connect negative pole of input voltage
with mark L of terminal block, using DC voltage for input voltage.
File Name:SE-350-SPEC 2012-02-28