1500W Single Output Power Supply
SE-1500 series
Features :
AC input 180 ~ 264VAC
AC input active surge current limiting
Protections: Short circuit / Overload / Over voltage / Over temperature
Forced air cooling by built-in DC ball bearing fan
High power density 7.8w/inch3
With DC OK signal output
Built-in remote ON-OFF control
Built-in remote sense function
UL / CUL approved
Low cost
2 years warranty
SPECIFICATION
MODEL
SE-1500-5
SE-1500-12
SE-1500-15
SE-1500-24
SE-1500-27
SE-1500-48
DC VOLTAGE
5V
12V
15V
24V
27V
48V
RATED CURRENT
CURRENT RANGE
RATED POWER
300A
125A
100A
62.5A
55.6A
31.3A
0 ~ 300A
1500W
0 ~ 125A
1500W
150mVp-p
10.8 ~ 13.5V
1.0%
0 ~ 100A
1500W
150mVp-p
13.5 ~ 16.5V
1.0%
0 ~ 62.5A
1500W
150mVp-p
21.6 ~ 26.4V
1.0%
0 ~ 55.6A
1501.2W
150mVp-p
25 ~ 30V
1.0%
0 ~ 31.3A
1502.4W
150mVp-p
43.2 ~ 56V
1.0%
RIPPLE & NOISE (max.) Note.2 150mVp-p
VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE Note.3 2.0%
OUTPUT
3.3 ~ 5.5V
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
0.5%
2.0%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
150ms, 12ms / 230VAC at full load
26ms / 230VAC at full load
VOLTAGE RANGE
180 ~ 264VAC
47 ~ 63Hz
254 ~ 370VDC
FREQUENCY RANGE
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
81%
85%
85%
87%
88%
89%
INPUT
17.5A / 230VAC
60A / 230VAC
<3.5mA / 240VAC
LEAKAGE CURRENT
105 ~ 125% rated output power
Protection type : Shut down o/p voltage, re-power on to recover
5.75 ~ 6.75V 14.5 ~ 16.2V 18 ~ 21V
Protection type : Shut down o/p voltage, re-power on to recover
95 (5V), 85 (12V,15V), 80 (24V), 75
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
PSU turn on:3.3V ~ 5.6V PUS turn off:0 ~ 1V
OVERLOAD
27.6 ~ 32.4V
31 ~ 35V
57.6 ~ 67.2V
PROTECTION
OVER VOLTAGE
5
5
5
5 (27V,48V) (TSW1) detect on heatsink of o/p diode
OVER TEMPERATURE
DC_OK SIGNAL
FUNCTION
RC+/RC-: 0 ~ 0.8V power on; 4 ~ 10V power off
-20 ~ +70 (Refer to "Derating Curve")
20 ~ 90% RH non-condensing
REMOTE CONTROL
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
-40 ~ +85 , 10 ~ 95% RH
ENVIRONMENT
0.05%/ (0 ~ 50
)
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
UL60950-1 approved
SAFETY STANDARDS
WITHSTAND VOLTAGE
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
SAFETY
ISOLATION RESISTANCE
MTBF
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
134.5K hrs min. MIL-HDBK-217F (25
278*177.8*63.5mm (L*W*H)
)
OTHERS
NOTE
DIMENSION
3.3Kg; 4pcs/14.2Kg/1.14CUFT
PACKING
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
File Name:SE-1500-SPEC 2011-08-23