SBL40U100F
Voltage 100V 40.0 Amp
Low VF Trench Barrier Schottky Rectifier
Elektronische Bauelemente
RoHS Compliant Product
A suffix of “-C” specifies halogen free
ITO-220
FEATURES
B
N
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
Trench MOS Schottky technology
Low forward voltage drop
Low reverse current
High current capability
High reliability
D
E
M
J
A
C
High surge current capability
Epitaxial construction
H
L
MECHANICAL DATA
ꢀ
ꢀ
ꢀ
Case: Molded plastic
Epoxy: UL94V-0 rate flame retardant
Lead: Lead solderable per MIL-STD-202
method 208 guaranteed
K
L
G
F
ꢀ
ꢀ
ꢀ
Polarity: As Marked
Mounting position: Any
Weight: 1.98 g (Approximate)
Millimeter
Millimeter
REF.
REF.
Min.
14.60
Max.
16.50
10.50
14.00
5.10
3.2
Min.
2.70
0.90
0.50
2.34
2.40
φ 3.0
Max.
4.00
1.50
0.95
2.74
3.60
φ 3.4
A
B
C
D
E
F
H
J
K
L
M
N
9.50
12.60
4.30
2.30
2.30
0.30
1
3
2
3.10
0.75
G
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
(Rating 25°C ambient temperature unless otherwise s pecified. Single phase half wave, 60Hz, resistive or inductive load.
For capacitive load, de-rate current by 20%.)
Parameter
Symbol
Rating
Unit
Maximum Recurrent Peak Reverse Voltage
Working Peak Reverse Voltage
VRRM
VRSM
VDC
100
100
100
20
V
V
V
Maximum DC Blocking Voltage
Maximum Average Forward Rectified
Current
(Per Leg)
A
IF
40
(Per Device)
IFSM
250
A
Peak Forward Surge Current, 8.3 ms single half sine-wave
Voltage Rate of Chance (Rated VR)
dv/dt
10000
4
V / µs
°C /W
°C
Typical Thermal Resistance
Rθ
JC
Operating and Storage Temperature Range
TJ,TSTG
-40~150
ELECTRICAL CHARACTERISTICS
Parameter
Symbol
Typ.
Max.
0.47
0.63
0.73
0.8
-
Unit
Test Condition
IF = 3A, TJ = 25°C
0.44
0.58
0.67
0.75
0.7
-
IF = 10A, TJ = 25°C
IF = 15A, TJ = 25°C
IF = 20A, TJ = 25°C
IF = 20 A, TJ = 125°C
TJ=25°C
Maximum Instantaneous Forward
Voltage
VF
V
0.2
20
Maximum DC Reverse Current
at Rated DC Blocking Voltage 2
Typical Junction Capacitance 1
IR
mA
pF
-
TJ=100°C
CJ
740
-
NOTES:
1. Measured at 1MHz and applied reverse voltage of 5.0V D.C.
2. Pulse Test:Pulse Width = 300 µs, Duty Cycle ≦ 2.0%.
http://www.SeCoSGmbH.com/
Any changes of specification will not be informed individually.
02-Jul-2014 Rev. A
Page 1 of 2