S8AS
Item
Model
S8AS-48008
S8AS-48008N
S8AS-48008R
Ambient operating temperature
Storage temperature
Refer to the derating curve (no icing or condensation). *2
−25 to 65°C
Ambient operating humidity
25% to 85% (storage: 25% to 90%)
3.0 kVAC for 1 min between all input terminals collectively and all branch output, all I/O signal, and all communications
terminals collectively (Detection current: 20 mA)
2.0 kVAC for 1 min between all inputs and protective earth (Detection current: 20 mA)
1.0 kVAC for 1 min between protective earth and all branch output, all I/O signal, and all communications terminals
collectively (Detection current: 30 mA)
Withstand voltage
500 VAC for 1 min between all branch output and all I/O signal/communications terminals collectively
(Detection current: 20 mA)
500 VAC for 1 min between all I/O signal terminals collectively and communications terminals collectively
(Detection current: 20 mA)
500 VAC for 1 min between all I/O signal terminals collectively and all output signal terminals collectively
(detection current: 20 mA)
Others
100 MΩ min. at 500 VDC between the protective earth terminal or all input terminals collectively and all branch output, all I/
O signal, and all communications terminals collectively
Insulation resistance
Vibration resistance
Shock resistance
Output indicator
Conducted EMI
Radiated EMI
No abnormality after 10 to 55 Hz at 0.375-mm single amplitude for 2 h each in 3 directions.
No abnormality after 150 m/s2 3 times each in 6 directions.
Provided (Color: green)
Conforms to EN 61204-3 Class A and FCC Class A.
Conforms to EN 61204-3 Class A.
cULus: UL508 (Listing. Class2: Per UL1310), CSA C22.2 No.107.1 (Class2: Per CSA C22.2 No.22.3)
cURus: UL60950-1, CSA C22.2 No.60950-1
EN: EN50178, EN60950-1
Safety standards (pending)
Weight
VDE: VDE0160, VDE0805 Teil1
2,400 g max.
*1. Do not use an inverter output for the Power Supply. Inverters with an output frequency of 50/60 Hz are available, but the rise in the internal
temperature of the Power Supply may result in ignition or burning.
*2. Refer to Engineering Data on page 8 for details.
*3. If the output voltage adjuster (V. ADJ) is turned, the voltage will increase by more than 10% of the voltage adjustment range. When adjusting
the output voltage, confirm the actual output voltage from the Power Supply and be sure that the load is not damaged. If the output voltage
exceeds 28.8 V, all branch outputs will be cut off.
*4. Rated input and output conditions: Rated input voltage, rated frequency, rated output voltage, rated total output current, and maximum cutoff
output current.
*5. 100% load conditions: Rated output voltage, rated total output current, and maximum cutoff output current.
5