Bu s s m a n n
5 x 2 0 m m Fe rru le Fu s e s
GDC
Tim e -De la y, Lo w Bre a k in g Ca p a c it y
GDC-V
Dimensional Data
Time-Current Characteristic Curves–Average Melt
38.10mm
(±.38)
.22mm
(±.008)
AMPERE
RATING
21.10mm
(±.81)
100
10mm 20mm
(±2.0) (±0.5)
38.10mm
(±.38)
5.2mm
(+0.1/-0.2)
10
.81mm
(REF)
Glass tube - end caps: nickel
or silver-plated brass.
CATALOG SYMBOL: GDC
TIME-DELAY, LOW BREAKING CAPACITY
250 VOLTS AC
1
UL RECOGNIZED:
(GUIDE #JDYX2, FILE #E75865)
Limits for Pre-arcing Time
1.5 In 2.1 In
MIN MAX
2.75 In
MIN MAX
4 In
10 In
MAX
.1
In
MIN MAX MIN
32mA - 100mA 60 min. 2 min. 200 ms. 10 sec. 40 ms. 3 sec. 10 ms. 300 ms.
125mA - 6.3A 60 min. 2 min. 600 ms. 10 sec. 150 ms. 3 sec. 20 ms. 300 ms.
8A - 12.5A
30 min. 5 min. 600 ms. 10 sec. 150 ms. 3 sec. 20 ms. 300 ms.
Packaging & Ordering Information:
.01
Product
Symbol
Lead
Ampere
Rating
CURRENT IN AMPERES
Package Code
GDC
Blank (None)
S506†
V
Axial Leads
.032” x 1.5”
Copper Tinned
Markings: MFG mark, Rated Current, Rated Voltage, Characteristic Symbol,
Breaking Capacity Symbol, Approvals where Applicable.
†S506 is a European designation. In North America, use GDC respectively when
referencing product, except 8, 10 and 12.5A.
CE logo denotes compliance with European Union Low Voltage Directive
(50-1000 VAC, 75-1500 VDC). Refer to BIF document #8002 or contact
Bussmann Application Engineering at 314-527-1270 for more information.
Form No. GDC
Page 1 of 2
12-18-98
SB98107
Rev. A
BIF Doc #2016