Multilayer Ceramic Capacitors
AEC-Q200
Approval Sheet
No.
AEC-Q200 Test Condition
Requirements
Test Item
17. Electrical
Characterization
* Capacitance
* Capacitance within the specified tolerance.
* Q. value
* Q. value: NPO: Cap≥30pF, Q≥1000 ; Cap<30pF, Q≥400+20C.
Cap≤1000pF 1.0±0.2Vrms, 1MHz±10%
Cap>1000pF 1.0±0.2Vrms, 1KHz±10%
* Test temp.: Room Temperature.
* Insulation Resistance
* IR. ≥10GΩ or RxC≥500Ω-F whichever is smaller.
To apply rated voltage(500V max.) for max. 120 sec
* Test temp.: Room Temperature..
* Dielectric Strength
* Dielectric strength
To apply voltage:
No evidence of damage or flash over during test.
≦100
≥2.5 times VDC
, duration 1~5 sec,
charge and discharge current less than 50mA.
* Temperature Coefficient (with no electrical load)
Operation temperature: -55~125°C at 25°C
* Temperature Coefficient
Capacitance Change: NPO: Within ±30ppm/°C
18.
Board Flex
* The middle part of substrate shall be pressurized by * No remarkable damage.
AEC-Q200-005
means of the pressurizing rod at a rate of about 1
* Cap change: NPO: within ±5% or 0.5pF whichever is larger
mm per second until the deflection becomes 5 mm (This capacitance change means the change of capacitance under specified
and then the pressure shall be maintained for 60±1 flexure of substrate from the capacitance measured before the test.)
sec.
* Measurement to be made after keeping at room
temp. for 24±2 hrs.
19.
Terminal Strength * Pressurizing force:
AEC-Q200-006 2N (0201 & 0402), 10N(0603), 18N(≥0805).
* No remarkable damage or removal of the terminations.
* Capacitance within the specified tolerance.
* Test time: 60±1 sec.
* Q. value: NPO: Cap≥30pF, Q≥1000 ; Cap<30pF, Q≥400+20C.
20 Beam Load Test
* Break strength test
The chip endure following force
AEC-Q200-003
* Beam speed: 2.5±0.25 mm/sec
* Chip length ≤2.5mm: Thickness >0.5mm (20N), ≤0.5mm (8N)
* Chip length ≥3.2mm: Thickness ≥1.25mm (54.5N), <1.25mm (15N)
21 ESR
The ESR should be measured at room temperature
and tested at frequency 1±0.1 GHz.
0402
0.1pF≤Cap≤1pF:< 350mΩ/pF
1pF<Cap≤5pF:< 300mΩ
5pF<Cap≤100pF:< 250mΩ
* "Room condition" Temperature: 15 to 35°C, Relativ e humidity: 25 to 75%, Atmospheric pressure: 86 to 106kPa.
Page 7 of 10
ASC_Microwave_AECQ200_RT
Feb. 2023