Approval sheet
Temperature cycle
JIS C 0025
1. 303 minutes at -40C3C,
No mechanical damage.
Electrical specification shall satisfy the
descriptions in electrical characteristics under
the operational temperature range within -40
~ 85°C.
2. 10~15 minutes at room
temperature,
3. 303 minutes at +85C3C,
4. 10~15 minutes at room
temperature,
Total 100 continuous cycles
Measurement to be made after keeping at
room temperature for 242 hrs
*Temperature:85C2C
High temperature
JIS C 0021
No mechanical damage.
Electrical specification shall satisfy the
descriptions in electrical characteristics under
the operational temperature range within -40
~ 85°C.
*Test duration:1000+24/-0 hours
Measurement to be made after keeping at
room temperature for 242 hrs
Humidity
*Humidity:90% to 95% R.H.
*Temperature:402C
*Time:1000+24/-0 hrs.
No mechanical damage.
(steady conditions)
JIS C 0022
Electrical specification shall satisfy the
descriptions in electrical characteristics under
the operational temperature range within -40
~ 85°C.
Measurement to be made after keeping
at room temperature for 242 hrs
※
500hrs measuring the first data then
1000hrs data
Low temperature
JIS C 0020
*Temperature:-40C2C
No mechanical damage.
Electrical specification shall satisfy the
descriptions in electrical characteristics under
the operational temperature range within -40
~ 85°C.
*Test duration:1000+24/-0 hours
Measurement to be made after keeping at
room temperature for 242 hrs
Page 7 of 9
ASC_RFANT3216120A5T_V09
Aug. 2018