EUROLINE - DC/DC-Converter
RxxC and RxxD Series, 2 Watt, DIP14/SIP7, Isolated (Dual Output)
Absolute Maximum Ratings
Input Voltage VIN
05V types
ꢀVDC
15VDC
28VDC
54VDC
12V types
24V types
48V types
Short Circuit Duration 1)
1 s
300mW
300°C
Internal Power Dissipation
Lead Temperature (1.5mm from case for 10 seconds)
1). Supply voltage must be discontinued at the end of the short circuit duration.
Electrical Specifications (measured at TA = 25°C, at nominal input voltage and rated output current unless otherwise specified)
Input Voltage Range VIN (continuous operation)
5V types
12V types
24V types
48V types
4.5VDC min. / 5.5VDC max.
10.8VDC min. / 13.2VDC max.
21.6VDC min. / 26.4VDC max.
43.2VDC min. / 52.8VDC max.
Reflected Ripple Current (depending on the type)
Output Voltage Accuracy (depending on the type)
Line Regulation (highVIN to low VIN)
50 mA p-p min. to 200 mA p-p max.
–5% min. / ꢀ.5% max.
1.0% min. / 1.2% max. of VIN
3% typ. / 10% max.
Load Regulation (10% load to rated load) (depending on the type)
Ripple and Noise (BW=DC to 20MHz) (depending on the type)
Isolation Voltage (flash tested for 1 second)
Test Voltage (50Hz, 10 seconds)
ꢀ0mVp-p min. / 200mVp-p max.
1000VDC min.
1000 Vpk min.
Resistance (Viso = 500V)
1GΩ min. / 10 GΩ typ.
80kHz min. / 95kHz max.
Switching Frequency at Full Load (depending on the type)
Package Weight
SIP types
DIP types
2.ꢀ6 g
2.85 g
Efficiency (100% load)
ꢀ0% min.
300mW typ.
Power Consumption (0% load)
Operating Temperature Range (all output types)
Storage Temperature Range
–40°C min. to +85°C max. (see graph)
–50°C to +130°C
Case Temperature Above Ambient (depending on the type)
MTTF 2) (depending on the type))
+25°C min. / +30°C max.
–40°C
+25°C
+85°C
134kHrs min. / 2004kHrs max.
112kHrs min. / 15ꢀ4kHrs max.
93kHrs min. / 1101kHrs max.
2). Calculated using MIL-HDBK-21ꢀF with nominal input voltage at full load.
Please contact us, if you need exact parameters for the converter you have selected.