2
QME48T40 Series
1.
Conditions: TA = 25ºC, Airflow = 300 LFM (1.5 m/s), Vin = 48 VDC, All output voltages, unless otherwise specified.
PARAMETER
CONDITIONS / DESCRIPTION
MIN
TYP
MAX
UNITS
Absolute Maximum Ratings
Input Voltage
Continuous
0
80
85
VDC
°C
Operating Ambient Temperature
Storage Temperature
Input Characteristics
Operating Input Voltage Range
Input Under Voltage Lockout
Turn-on Threshold
-40
-55
125
°C
36
48
75
VDC
33
31
34
32
35
33
VDC
VDC
VDC
Turn-off Threshold
Input Voltage Transient
Isolation Characteristics
I/O Isolation
100 ms
100
2000
10
VDC
nF
Isolation Capacitance
Isolation Resistance
2
MΩ
Feature Characteristics
Switching Frequency
Output Voltage Trim Range1
460
kHz
%
Non-latching (3.3 - 1.5 V)
Non-latching (1.2 V and 1.0 V)
Percent of VOUT(nom)
Non-latching
-20
-10
+10
+10
+10
140
%
Remote Sense Compensation1
Output Overvoltage Protection
Auto-Restart Period
%
117
128
200
4
%
Applies to all protection features
ms
ms
Turn-On Time
ON/OFF Control (Positive Logic)
Converter Off (logic low)
Converter On (logic high)
ON/OFF Control (Negative Logic)
Converter Off (logic high)
Converter On (logic low)
-20
2.4
0.8
20
VDC
VDC
2.4
-20
20
VDC
VDC
0.8
1)
Vout can be increased up to 10% via the sense leads or 10% via the trim function. However, the total output voltage trim from
all sources should not exceed 10% of VOUT(nom), in order to ensure specified operation of overvoltage protection circuitry