PT-54-TE Product Datasheet
Optical & Electrical Characteristics
Note 1:
Note 2:
Note 3:
All ratings are based on testing conditions with a constant heat sink temperature Ths = 40ºC. See Thermal Resistance section for Ths definition.
t
t
T
Parameters rated at test duty cycle and Pulsed operation frequency f>240 Hz; DC= --
T
Duty Cycle used to specify device ratings under Pulsed operation. LED devices can operate at duty cycles ranging from 1% to 100%. At higher duty cycles, drive
current should be adjusted to maintain the junction temperature at desired levels to meet the application lifetime requirements.
Note 4:
Note 5:
Note 6:
Note 7:
In pulsed operation, rise time from 10 to 90% of forward current should be larger than 0.5 microseconds
For Blue devices, total flux from emitting area at typical dominant wavelength. Refer to page 7 for brightness specifications at other wavelength
CIE 1931 chromaticity diagram coordinates, normalized to X+Y+Z=1
For Reference only
Absolute Maximum Ratings
Red-Amber
(Common
Cathode)
Symbol
Green
Blue
Unit
Absolute Minimum Current (CW or Pulsed)1
Absolute Maximum Current (CW) 2
200
200
200
mA
A
11ꢀ9
11.9
11.9
Absolute Maximum Current (Pulsed) 2,3
(frequency > 240Hz, duty cycle <70%)
Absolute Maximum Surge Current 2,3
16ꢀ2
18ꢀ9
16.2
16.2
A
18ꢀ9
18ꢀ9
A
(Frequency > 240 Hz, duty cycle =10%, t=1ms)
Maximum Operating Junction Temperature 4
Absolute Maximum Junction Temperature 4
Storage Temperature Range
Tj
100
125
140
170
130
170
oC
oC
oC
Tj abs. max
-40 / +100
-40 / +100
-40 / +100
Note 1:
Note 2:
Product performance and lifetime data is specified at recommended forward drive currents. Sustained operation at or near absolute minimum currents may
result in a reduction of device performance and device lifetime compared to recommended forward currents.
Maximum forward drive current conditions for continuous operation are 11.9 A, CW (2.2 A/mm2 ), and 16.2 A, f>240 Hz, duty cycle <70% ( 3.0 A/mm2 )ꢀ
Sustained operation above maximum currents is not recommended and will result in a reduction of device lifetime compared to specified maximum forward
drive currents. Device lifetimes will depend on junction temperature. (See Reliability Application Note, APN-001444 for product lifetimes as function of
junction temperature.) Please refer to lifetime de-rating curves (available from Luminus ) for further information.
Note 3:
Note 4:
In pulsed operation, rise time from 10 to 90% of forward current should be larger than 0.5 microseconds.
Sustained operation at or above Absolute Maximum Operating Junction Temperature (Tjmax) will result in reduced device life time. Device lifetimes will depend
on junction temperature. (See Reliability Application Note, APN-001444 for product lifetimes as function of junction temperature.) Please refer to lifetime
de-rating curves (available from Luminus ) for further information.
Luminus Devices, Inc. • T 978.528.8000
•
www.luminus.com
6
PDS-002026 Rev 07 © 2016 Luminus Devices, Inc. - All Rights Reserved
175 New Boston Street
• Woburn, MA 01801