描述
Application Boards for EPIC sensor

PS25012A2 数据手册

 浏览型号PS25012A2的Datasheet PDF文件第2页浏览型号PS25012A2的Datasheet PDF文件第3页 
PS25012A2, PS25012B2  
Application Boards for EPIC sensor PS25202  
Features  
Description  
The PS25012A2 and PS25012B2 are single and  
boards  
demonstration of the Plessey PS25202 electric  
potential sensor.  
Ultra high input resistance, typically 5x1010 .  
dual  
channel  
application  
for  
the  
Frequency response (-3dB) 50mHz to 4.0kHz.  
Wide operating voltage from 4.0 to 8.0V.  
Operating temperature range 0 to 50ºC.  
200pF load drive capability.  
The PS25202 electric potential sensors on these  
boards allow the measurement of a wide range of  
electric potential sources from electrophysiological  
signals through to spatial electric field. The sensors  
incorporate a DC block feature that allows the DC  
component of an applied signal to be rejected while  
maintaining good low frequency response. The  
electrode surface of the detector is passivated with a  
thin dielectric that allows the direct application to a  
test surface. In the case of contact with skin there is  
no need for electrically conductive gel.  
Ground referenced output.  
DC signal rejection.  
Dual sensor board allows differential operation.  
Applications  
Electrophysiological signal detection.  
ECG/EOG/EMG/EEG  
Electric field and potential sensing.  
Movement sensing  
The PS25202 sensor demonstrated on these boards  
is an integrated assembly designed for surface  
mount assembly on a motherboard.  
The application boards provide the regulated +2.5V  
and generated -2.5V supplies that are used to  
operate the sensor. This allows the boards to  
demonstrate the sensors from a wide, single sided,  
power supply voltage while the output of the sensor  
can cover the range 2.1V. The boards are  
connected by a high reliability five pin connector.  
Two single channel PS25012A2 boards or a dual  
channel PS25012B2 board may be used to generate  
a differential signal. A typical example is shown in  
Figure 3 below:  
Figure 1: PS25012A2 single channel board carrying a  
single PS25202 sensor  
Figure 3: Differential signal from two sensors in  
contact with the skin showing ECG type  
characteristics  
Figure 2: PS25012B2 dual channel board carrying  
two PS25202 sensors  
Data Sheet 291502 issue 1  
Plessey Semiconductors Ltd.  
Design & Technology Centre, Delta 500, Delta Business Park, Great Western Way, Swindon, UK SN5 7XE  
Tel: +44 1793 518000 Fax: +44 1793 518030 Web: www.plesseysemi.com  
1

与PS25012A2相关器件

型号 品牌 获取价格 描述 数据表
PS25012A3 ETC

获取价格

Application Boards for EPIC sensor
PS25012A4 ETC

获取价格

APPLICATION BOARDS FOR EPIC SENSOR PS25204
PS2501-2-A-N NEC

获取价格

暂无描述
PS2501-2-A-N CEL

获取价格

Transistor Output Optocoupler, 2-Element, 5000V Isolation, LEAD FREE, PLASTIC, DIP-8
PS25012B1 ETC

获取价格

APPLICATION BOARDS FOR EPIC SENSOR PS25201A
PS25012B4 ETC

获取价格

APPLICATION BOARDS FOR EPIC SENSOR PS25204
PS2501-2-D RENESAS

获取价格

2 CHANNEL TRANSISTOR OUTPUT OPTOCOUPLER, PLASTIC, DIP-8
PS2501-2-E4-XXX NEC

获取价格

Transistor Output Optocoupler, 2-Element, 5000V Isolation, PLASTIC, DIP-8
PS2501-2-G ISOCOM

获取价格

Optocoupler - Transistor Output, 2 CHANNEL TRANSISTOR OUTPUT OPTOCOUPLER, ROHS COMPLIANT,
PS2501-2GR ISOCOM

获取价格

Transistor Output Optocoupler, 2-Element, 5300V Isolation, DIP-8