DC-AC INVERTER UNIT
PS-DA0211-01(S) (12 W DUAL OUTPUTS)
Input side CN1:
(PRELIMINARY INFORMATION)
Output side CN2:
Pin No. Symbols
Ratings
Pin No.
CN 2-1
CN 2-2
Symbols
Vhigh
Ratings
800 Vrms (7.5 mArms)
(GND)
Vin
GND
Vbr
12 Vdc
CN 1-1
CN 1-2
CN 1-3
CN 1-4
CN 1-5
Vlow
0 ~ 4.2 Vdc
GND
Vrmt
Output side CN3:
0 ~ 0.4 = OFF / 3 ~ Vin = ON
Pin No.
CN 3-1
CN 3-2
Symbols
Ratings
800 Vrms (7.5 mArms)
(GND)
Vhigh
Vlow
ELECTRICAL CHARACTERISTICS :
Conditions
Specification
Parameters
Symbols
Unit
Note
Vin (V) Vbr (V) Tu (°C)
Min.
Typ.
Max.
Iout
Iout
Iin
12±1.2
12±0.6
12±1.2
12±1.2
11.4
0.0
4.2
0.0
0.0
0.0
0.0
0 ~ +50
0 ~ +50
0 ~ +50
0 ~ +50
7.0
2.5
-
7.5
3.0
8.0
3.5
mArms
mArms
Adc
Output Current
Output Current
Input Current
0.93
52
1.4
F
44.5
59.5
1.700
-
kHz
Frequency
Vopen
Tsd
0 ~ +50 1.300
0 ~ +50 1.0
1.500
-
Vrms
sec
Open Circuit Voltage
No load Shutdown
without load
12±1.2
Note 1 :
Please keep minimum of 2mm clearance (all directions) between inverter high voltage area as marked
on mechanical drawing and any conductors.
TEST CIRCUIT :
F
1000:1
PROBE
F
SW1
a
Operation of unit
Operation
V
Vopen
RL1
Iin
~
A
Vin
12 V
CN1-1
CN1-2
CN1-3
SW3
V
Non operation
CN2-1
b
CL1
A
~
T1
Iout1
CN2-2
CN3-1
SW4
SW5
Vbr
0 ~ 4.2 Vdc
CN1-4
CN1-5
RL2
CL2
a
Vrmt
0.4 / 3 Vdc
A
~
b SW1
V
Iout2
SW6
CN3-2
Power Systems – The Power Solution
Web:
www.Power-Systems.de
Info@Power-Systems.de
Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany
Email:
Tel. :
Fax:
+ 49 / 70 62 / 67 59 - 6
+ 49 / 70 62 / 67 59 - 800
All specifications are subject to change without notice.
Page (2)
Version 1.9.1, 7th July 2008