Power Derating Curve
100
80
Natural
convection
60
40
20
0
~
110
100
-40
0
20
40
60
80
C
Ambient Temperature
Notes
1
2
3
4
5
Specifications typical at Ta=+25℃, resistive load, nominal input voltage, rated output current unless otherwise noted.
Ripple & Noise measurement bandwidth is 0-20 MHz.
All DC/DC converters should be externally fused at the front end for protection.
That “natural convection” is about 20LFM but is not equal to still air (0 LFM).
Specifications subject to change without notice.
Mechancial Drawing
Mechanical Dimensions
Pin Connections
Pin
Single Output
Dual Output
-Vin
17.0 [0.67]
1
-Vin
2
+Vin
+Vin
4
+Vout
+Vout
5
6
No Pin
-Vout
Common
-Vout
0.5
[0.02]
2.15
2.54 5.08
2X2.54
[0.08]
[0.10] [0.20] [2X0.10]
16.0 [0.63]
Bottom View
2
5
6
1
4
►All dimensions in mm (inches)
►Tolerance: X.X±0.5 (X.XX±0.02)
X.XX±0.25 ( X.XXX±0.01)
►Pins ±0.05(±0.002)
0.50 [0.02]
Physical Outline
Case Size
Case Material
Pin Material
Weight
:
:
:
:
17.0x7.62x11.0mm (0.67x0.30x0.43 inches)
Non-Conductive Black Plastic (flammability to UL 94V-0 rated)
Alloy 42
12.9g
DS_PL01S/D_07192012
E-mail: DCDC@delta.com.tw
http://www.delta.com.tw/dcdc