250W Isolated Dual Output with PFC Function
PID-250
Features :
Universal AC input / Full range
Isolated output & GND for CH1,CH2
Built-in active PFC function, PF>0.92
Protections:Short circuit / Overload / Over voltage / Over temperature
Remote control for CH1
Peak load 170% for CH1 within 10 sec.
Cooling by free air convection
100% full load burn-in test
3 years warranty
SPECIFICATION
MODEL
PID-250A
PID-250B
PID-250C
PID-250D
OUTPUT NUMBER
CH1
12V
CH2
5V
CH1
24V
CH2
5V
CH1
36V
CH2
5V
CH1
48V
CH2
5V
DC VOLTAGE
RATED CURRENT
15A(Peak 20A) 5A
9.4A(Peak 16.7A) 5A
6.3A(Peak 11.1A) 5A
4.7A(Peak 8.4A) 5A
0 ~ 15A
(Peak 20A)
0 ~ 5A
0 ~ 9.4A
(Peak 16.7A)
0 ~ 5A
0 ~ 6.3A
(Peak 11.1A)
0 ~ 5A
0 ~ 4.7A
(Peak 8.4A)
0 ~ 5A
CURRENT RANGE
RATED POWER
Note.6
205W
250.6W
251.8W
250.6W
RIPPLE & NOISE (max.) Note.2 120mVp-p
VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE Note.3 3.0%
50mVp-p
150mVp-p
50mVp-p
200mVp-p
50mVp-p
200mVp-p
50mVp-p
OUTPUT
10.8 ~ 13.2V 4.75 ~ 5.25V 21.6 ~ 26.4V 4.75 ~ 5.25V 32.4 ~ 39.6V 4.75 ~ 5.25V 43.2 ~ 52.8V 4.75 ~ 5.25V
2.0%
0.5%
2.0%
2.0%
0.5%
1.0%
2.0%
0.5%
2.0%
2.0%
0.5%
1.0%
2.0%
0.5%
2.0%
2.0%
0.5%
1.0%
2.0%
0.5%
2.0%
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
0.5%
1.0%
2500ms, 60ms/115VAC 1200ms, 60ms/230VAC
30ms at full load
VOLTAGE RANGE
Note.5 90 ~ 264VAC
127 ~ 370VDC
FREQUENCY RANGE
POWER FACTOR
47 ~ 63Hz
PF 0.92/230VAC
83%
PF 0.97/115VAC at full load
86%
INPUT
EFFICIENCY(Typ.)
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
86%
86%
3A/115VAC
1.5A/230VAC
COLD START 58A/230VAC
<3.5mA / 240VAC
LEAKAGE CURRENT
CH1: 105 ~ 170% rated output power
Normally work within 10 sec and then shut down, re-power on to recover
Over 180% rated power or short circuit, constant current limiting within 10 sec and then shut down, re-power on to recover
CH2: 101 ~ 150% rated output power
OVERLOAD
Protection type : Hiccup mode, recovers automatically after fault condition is removed
PROTECTION
13.8 ~ 16.2V 5.5 ~ 6.75V
27.6 ~ 32.4V 5.5 ~ 6.75V
40 ~ 48V
5.5~ 6.75V
54 ~ 64.8V
5.5 ~ 6.75V
Protection type : Shut down o/p voltage, re-power on to recover for CH1 ; Hiccup mode, recovers automatically afer fault condition
is removed for CH2(by zener diode clamp)
OVER VOLTAGE
105
5
detect on heatsink of power transistors
OVER TEMPERATURE
Protection type : Shut down o/p voltage(CH1), recovers automatically after temperature goes down
CN52 : Open=CH1 & CH2 power on ; Short = CH1 power off, CH2 power on; when CH2 is malfunction, CH1 will be shut down
-20 ~ +70 (Refer to output load derating curve)
FUNCTION REMOTE CONTROL
WORKING TEMP.
20 ~ 90% RH non-condensing
WORKING HUMIDITY
-20 ~ +85 , 10 ~ 95% RH
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
0.05%/ (0 ~ 50
10 ~ 500Hz, 2G 10min./1cycle, period for 60min each along X, Y, Z axes
UL60950-1, TUV EN60950-1 approved
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
SAFETY &
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC 25 70%RH
Compliance to EN55022 (CISPR22) Class B
ISOLATION RESISTANCE
EMC
EMI CONDUCTION & RADIATION
(Note 4)
HARMONIC CURRENT
EMS IMMUNITY
MTBF
Compliance to EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN61000-6-2, heavy industry level, criteria A
150.4Khrs min. MIL-HDBK-217F (25
)
OTHERS
NOTE
DIMENSION
PACKING
222*95*40mm open frame type (L*W*H), 250*105.4*53mm enclosed type (L*W*H)
0.74Kg; 18pcs/14.3Kg/0.88CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
5. Derating may be needed under low input voltage. Please check the derating curve for more details.
6. Peak current should reduce to 150% of rated value if the input voltage <110VAC.
File Name:PID-250-SPEC 2008-03-25