30 Watts
xppower.com
PDM30 Series
•
•
•
•
•
•
•
CEC2008 & EISA2007 Compliant ≥9 V
Worldwide Medical Approvals
4000 VAC Isolation
Class II Construction
Single Outputs from 5 V to 24 V
High Efficiency
Operation to +60 °C
Specification
Input
General
Input Voltage
• 90-264 VAC
Efficiency
• 82ꢀ typical
Input Frequency
Input Current
• 47-63 Hz
Isolation
• 4000 VAC Input to Output
• 70 kHz typical
• 3 W/Inch3
• 0.6 A rms max
Switching Frequency
Power Density
MTBF
Inrush Current
Input Protection
• 50 A max at 264 VAC
• Fitted with a T2 A/250 VAC fuse in live line
• 500 kHrs to MIL-STD-217F
Output
Environmental
Output Voltage
• See table
Operating Temperature • 0 ꢁC to +60 ꢁC, derate from 100ꢀ load at
+40 ꢁC to 60ꢀ load at +60 ꢁC for 5, 9 &
12 V models. Derate from 100ꢀ load at
+50 ꢁC to 80ꢀ load at +60 ꢁC for 15, 18 &
24 V models
Initial Set Accuracy
Minimum Load
•
2ꢀ set at 60ꢀ load
• No mimimum load required
• 3 s max
Start Up Delay
Start Up Rise Time
Hold Up Time
• 2 ms
Cooling
• Convection-cooled
• 16 ms minimum at 115 VAC
Operating Humidity
Storage Temperature
Operating Altitude
Vibration
• 15-95ꢀ non-condensing
• -20 ꢁC to +85 ꢁC
Line Regulation
Load Regulation
Transient Response
•
1ꢀ
• See tables
• 3000 m
• 5ꢀ max deviation recovering to within 1ꢀ
within 500 µs for 50ꢀ load change
• 5-500 Hz at 3 g for 10 mins on each axis
Shock
• 30 g with 18 ms half sine wave,
3 times on each axis
Ripple & Noise
• 1ꢀ max, 20 MHz BW see note 2
Overvoltage Protection • See tables
Overload Protection • 120-150ꢀ
Short Circuit Protection • Trip & restart (hiccup mode), auto-recovery
EMC & Safety
Emissions
• EN55011 Level B conducted & radiated
• EN61000-3-2
Temperature
Coefficient
•
0.05ꢀ/ꢁC
Harmonic Currents
Voltage Flicker
ESD Immunity
Radiated Immunity
EFT/Burst
• EN61000-3-3
• EN61000-4-2 Level 3, Perf Criteria A
• EN61000-4-3 Level 2, Perf Criteria A
• EN61000-4-4, Level 3, Perf Criteria A
• EN61000-4-5 Level 3, Perf Criteria A
• EN61000-4-6 Level 3, Perf Criteria A
Surge
Conducted Immunity
Dips & Interruptions
T
• EN61000-4-11, 70ꢀ U for 500 ms,
T
T
40ꢀ U for 100 ms, <5ꢀ U for 5000 ms
Perf criteria A, B, B
Safety Approvals
• UL60601-1, EN60601-1, IEC60601-1,
CE Mark