Ordering information
AC-DC Power Supplies Enclosed Type
PC
A
300
F
-5
-O
6
PCA300F
1ꢀ
2ꢀ
3ꢀ
4ꢀ
5ꢀ
1Series name
2Single output
Example recommended EMI/EMC filter
NAC-06-472
R
3Output wattage
4Universal input
5Output voltage
6Optional *7
C :with Coating
G :Low leakage current
T :Terminal Block Style
I :with PMBus interface
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
F2
P3
:
:
Reverse air exhaust type
Master-slave Operation
*
Aꢀhigher current rating EMI/EMC filter
may be recommended in view of the
other devices that could be connected
in parallel with the power supply.
W1:Alarm function
2MOPP
For option details, refer to
instruction manual 7.1.
Terminal Block Style
*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.
MODEL
MAX OUTPUT WATTAGE[W]
DC OUTPUT
PCA300F-5
300
PCA300F-12
324
PCA300F-15
330
PCA300F-24
336
PCA300F-32
320
PCA300F-48
336
5V 60A
12V 27A
15V 22A
24V 14A
32V 10A
48V 7A
SPECIFICATIONS
MODEL
PCA300F-5
85 - 264 1f
88 - 370
PCA300F-12
PCA300F-15
PCA300F-24
PCA300F-32
PCA300F-48
[VAC]
[VDC]
VOLTAGE
*1
ACIN 100V
ACIN 230V
3.8typ
CURRENT[A]
1.6typ
FREQUENCY[Hz]
50/60 (45 - 66)
86typ
(Io=50%)
87typ
88typ
88typ
90typ
87typ
88typ
88typ
90typ
88typ
89typ
89typ
91typ
88typ
89typ
89typ
91typ
88typ
89typ
89typ
91typ
ACIN 100V
ACIN 230V
(Io=100%)
(Io=50%)
87typ
INPUT
EFFICIENCY[%]
87typ
(Io=100%)
ACIN 100V
ACIN 230V
89typ
0.98typ (Io=100%)
0.95typ (Io=100%)
POWER FACTOR
*2
ACIN 100V
ACIN 230V
20/40 typ (Io=100%) (Primary inrush current / Secondary inrush current) (More than 3 sec. to re-start)
40/40 typ (Io=100%) (Primary inrush current / Secondary inrush current) (More than 3 sec. to re-start)
0.5max (ACIN 240V 60Hz, Io=100%, According to IEC60601-1)
INRUSH CURRENT[A]
*2
LEAKAGE CURRENT[mA]
VOLTAGE[V]
5
12
15
24
32
48
CURRENT[A]
60
27
22
14
10
7
LINE REGULATION[mV]
LOAD REGULATION[mV]
20max
40max
160max
280max
240max
320max
50max
75max
20max
48max
100max
240max
320max
300max
360max
120max
180max
48max
60max
120max
240max
320max
300max
360max
150max
180max
60max
96max
150max
240max
320max
300max
360max
240max
290max
96max
128max
150max
320max
420max
400max
480max
320max
400max
128max
192max
480max
480max
640max
600max
720max
480max
600max
192max
*3*4
*3
0 to +50C
RIPPLE[mVp-p]
-20 to 0C
0 to +50C
-20 to 0C
0 to +50C
*3*4
*3
RIPPLE NOISE[mVp-p]
TEMPERATURE REGULATION[mV]
OUTPUT
*4
*4
-20 to +50C
*
5
DRIFT[mV]
START-UP TIME[ms]
HOLD-UP TIME[ms]
700typ (ACIN 100/230V Io=100%)
20typ (ACIN 230V Io=80%) / 16typ (ACIN 230V Io=100%)
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
OUTPUT VOLTAGE SETTING[V]
OVERCURRENT PROTECTION
OVERVOLTAGE PROTECTION[V]
REMOTE SENSING
3.00 to 6.00
5.00 to 5.05
7.20 to 14.40
12.00 to 12.12
9.00 to 18.00
15.00 to 15.15
14.40 to 28.80
24.00 to 24.24
19.20 to 38.40
32.00 to 32.32
28.80 to 57.60
48.00 to 48.48
Works over 105% of rating (Recovers automatically, Hiccup overcurrent)
6.25 to 7.00
Provided
15.00 to 16.80
18.75 to 21.00
30.00 to 33.60
40.00 to 44.80
60.00 to 67.20
PROTECTION
CIRCUIT AND REMOTE ON/OFF (RC)
Provided
OTHERS
DC_OK LAMP
LED (Blue)
LED (Orange)
ALARM LAMP
COMMUNICATION FUNCTION
INPUT-OUTPUT
INPUT-FG
Provided (Extended UART)
AC4,000V 1minute, Cutoff current = 10mA, DC500V 50MΩ min (At Room Temperature) 2MOPP
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MΩ min (At Room Temperature) 1MOPP
AC500V 1minute, Cutoff current = 100mA, DC500V 50MΩ min (At Room Temperature)
ISOLATION
OUTPUT-FG
OUTPUT - AUX-RC-PG-INFO-DS-ADDR0-ADDR1-ADDR2 AC500V 1minute, Cutoff current = 100mA, DC500V 50MΩ min (At Room Temperature)
OPERATING TEMP.,HUMIDITY.AND ALTITUDE
STORAGE TEMP.,HUMIDITY.AND ALTITUDE
VIBRATION
-20 to +70C, 20 - 90%RH (Non condensing)
-20 to +75C, 20 - 90%RH (Non condensing)
ENVIRONMENT
2
10 - 55Hz 19.6m/s (2G) 3minutes period, 60minutes each along X, Y and Z axis
2
IMPACT
196.1m/s (20G) 11ms, once each X, Y and Z axis
UL62368-1, EN62368-1, C-UL (equivalent to CAN/CSA-C22.2 No.62368-1), ANSI/AAMI ES60601-1, EN60601-1 3rd,
C-UL (equivalent to CAN/CSA-C22.2 No.60601-1), Complies with IEC60601-1-2 4th Ed.
AGENCY APPROVALS
CONDUCTED NOISE
SAFETY
AND NOISE
REGULATIONS
Complies with FCC Part15 classB, VCCI-B, CISPR32-B, EN55011-B, EN55032-B
Complies with IEC61000-3-2 (class A)
*
6
HARMONIC ATTENUATOR
PCA-2