PRV6, PARV6
Fully Sealed Potentiometers Cermet (PRV6)
Conductive Plastic (PARV6)
Vishay Sfernice
PANEL SEALING
STANDARD RESISTANCE ELEMENT DATA
Except for dia. 4 mm shaft, an O.ring is supplied with the
potentiometer. This O.ring should be placed into the groove
of the body and ensures the panel sealing.
For dia. 4 mm shaft please see note “P” in ordering
information.
PRV6 LINEAR LAW
MAX. MAX. MAX.
POWER WORKING WIPER POWER WORKING WIPER
PRV6 NON-LINEAR LAWS
STANDARD
RESIS-
TCR
- 55 °C
+ 125 °C
MAX. MAX. MAX.
TANCE
VALUES
AT 70 °C VOLTAGE
CUR.
AT 70 °C VOLTAGE
CUR.
SHAFTS
Ω
20
50
W
V
mA
W
V
mA
ppm/°C
Shaft lengths are measured from the mounting face to the
free end of the shaft. Special shafts are available if the
customer supplies a drawing. The shaft slot is aligned to the
wiper within 10°.
1.5
5.48
8.66
274
173
0
+ 200
100
200
500
1K
2K
5K
12.2
17.3
27.4
38.7
54.8
86.6
122.5
173
122
87
55
38.7
27.4
17.3
12.2
8.26
5.65
3.5
1.75
0.7
0.35
0.17
0.07
0.035
HARDWARE
0.75
27.3
38.2
61.2
87
122
194
273
350
350
27.4
19.3
12.2
8.7
Nuts, washer and O.ring are separately supplied (not
mounted on the potentiometer), in a small bag placed in the
packaging.
10K
20K
50K
100K
200K
500K
1M
6.1
PRV6
100
1.5
274
3.9
LOCATING PEG
1.22
0.61
0.25
0.12
0.06
350
0.75
0.61
0.25
2.74
1.75
0.7
350
Except for dia. 4 mm shaft, the potentiometers are delivered
with 2 opposite locating pegs orientated at 45°. These
2 pegs can be easily broken-off by the customer. On
request, the orientation of the pegs can be at 30° instead of
45°. Order Designation: PRV6 L (see ordering information)
350
350
2M
350
5M
0.025 350
0.012 350
10M
MARKING
PACKAGING
VISHAY trademark, series, style, ohmic value (in Ω , kΩ
or MΩ), tolerance in ꢀ, taper code, manufacturing date
(4 digits: 2 for year, 2 for week), terminal 1.
Carton box of 50, code: BO50
ORDERING INFORMATION
Solder Lugs
no code
PCB pins
code W
Code H
not available
for 6-6Q
versions
LOCKING SHAFT
PRV cermet
PARV conductive
BUSHING
plastic
22
Ω to 10 MΩ
linear law - cermet
470
Ω to 1 MΩ
SHAFT
DIA
d
SERIES
non-linear laws
cermet
TERMINALS
From mounting face
DIA LENGTH
DIA
d
LENGTH
1 k
Ω to 1 MΩ
CODE
L
D
6.35
6.35
6.35
7
B
linear law -
conductive
plastic
6
61
6.35
9.5
12.5
6.5
9.5
6.5
9.5
3 or 3.17
A: standard 45°
no code
A: option 30°
code L
not available
for 6Q and 61Q
versions
See drawing
LOCATING PEGS
*CK
CM
CD
CR
*K
M
3.17
3.17
3.17
3.17
3
9.5
12.5
16
S
L
6
470
Ω to 500 kΩ
3 or 3.17
61
non linear laws
Standard C = 9.5
no code
Option C = 12.1
code S
62
3 or 3.17
O
T
62
22
conductive plastic
61H
62H
9.5
12.5
22
470
Ω to 100 kΩ
6Q
4
4
4
4
T
E
D
3
non linear laws
R
3
61Q
6QP
61QP
7
conductive plastic
BODY LENGTH
6Q
61Q
E
4
9.5
12.5
22
7
F
4
OHMIC VALUE
61QH
G
4
7
* not available with 62H option
Shaft dia 3.17 and 3 are standard
panel sealed
Shaft dia 4: please note “P” for
panel sealed option
20 ꢀ standard
10 ꢀ optional
5 ꢀ optional
(cermet only)
STANDARD SHAFT LENGTH
SHAFTS and BUSHINGS
TOLERANCE
A
L
Linear
CW Log
VARIATION LAW
PACKAGING
BO50
PRV
S
61
W
L
H
CM
10 k
Ω
20 %
A
3
SAP PART NUMBERING GUIDELINES
P
R
V
6
B
B
L
B
B
X
B
2
5
1
0
M
A
PACKAGING
OHMIC VALUEꢁTOLꢁLAW
STYLE
SHAFT
PEG
LEADS
MODEL
OR SPECIAL
BUSHING
See the end of this data book for conversion tables
www.vishay.com
126
For technical questions, contact: sfer@vishay.com
See also: Application notes
Document Number: 51035
Revision: 29-Jun-06