PAH75S48
PAH75S48 Specifications
PAH75S48
MODEL
ꢀ
PAH75S48-2.5 PAH75S48-3.3 PAH75S48-5 PAH75S48-12 PAH75S48-15 PAH75S48-24 PAH75S48-28
ITEMS/UNITS
Voltage Range
Input Efficiency (typ)
Current (typ)
V
%
A
DC36 - 76
(*1)
(*1)
76
1.20
2.5
79
1.52
3.3
83
1.88
5
85
87
1.85
12
1.84
1.81
28
CC-E
Nominal Voltage
Minimum Current
Maximum Current
Maximum Power
VDC
A
15
24
CE-
0
09XX
A
17.5
15
6.3
5
3.2
2.7
W
43.75
57.75
75.0
75.6
±1.6
24
75.0
76.8
75.6
CE-
10XX
Voltage Setting Accuracy (*1)
%
Output Maximum Line Regulation(*4)(*12) mV
Maximum Load Regulation(*5)(*12) mV
Temperature Coefficient
10
10
30
30
48
48
56
56
CE-
24
3101
0.02%/℃
KS
KWS
KWD
Maximum Ripple & Noise (-20 to +100℃) (*3) mVp-p
Maximum Ripple & Noise (-40 to -20℃)(*3) mVp-p
Voltage Adjustable Range(*2)
150
300
200
240
300
280
350
250
±10%
+15%, -40%
+10%, -40%
PAE
PAF
PAH
PAQ
PF-A
PFE
PH
Over Current Protection (*6)
Over Voltage Protection (*7)
Over Temperature Protection
ꢀ
105 - 150%
120 - 160% 120 - 140%
125 - 145%
Inverter shutdown (Option available: Refer to option table)
Shutdown ; Auto-restart when unit cool down
Possible (Connect +S and -S terminals to load)
Negative logic (Option available: Refer to option table)
-
Function
Remote Sensing
(*10)
Remote ON/OFF Control (*8)
Parallel Operation
Series Operation
Possible
Operating Temperature
Storage Temperature
Operating Humidity
Storage Humidity
℃
℃
%RH
%RH
-40 to +100 (Baseplate) Ambient temperature min = -40
-40 to +100 (Baseplate) Ambient temperature min = -40
30 - 95 (No dewdrop)
30 - 95 (No dewdrop)
Environment
At no operating, 10 ~ 55Hz amplitude (sweep 1 min)
0.825mm constant (maximum 49.0m/s²) X, Y, Z 1 hr each
196.1m/s²
Vibration
Shock
PMH
Cooling
(*9)
Conduction cooled
Input - Output : 1.5kVAC, Input - Baseplate : 1.5kVAC (20mA) for 1 min
Output - Baseplate : .500VDC for 1 min
Withstand Voltage
Isolation
Isolation Resistance
More than 100MOHM at 25℃ and 70 %RH, Output - Baseplate : 500 VDC
Approved by UL60950-1, CSA-C 22.2 No.60950-1, EN60950-1.
80
Standards Safety Standards
Weight
Mechanical
g
Size (W x H x D)
mm
57.9 x 12.7 x 61 ( Refer to outline drawing)
(*1) At 48 VDC, maximum output power and baseplate temperature = +25℃.
(*2) Additional external components have to be connected; Refer to application notes.
(*3) External components are needed; Refer to basical connection drawing.
(*4) 36 - 76 VDC, constant load.
Option table:
Option
ON/OFF Logic
OVP
Negative
(H: OFF, L: ON)
Standard
Shut-down
(ON/OFF control reset or
manual reset)
(*5) No load - full load, constant input voltage.
(*6) Current limiting with automatic recovery.
Positive
(H: ON, L: OFF)
/P
/V
(*7) CNT reset or manual reset.
(*8) Refer to application notes.
Negative
(H: OFF, L: ON)
(*9) Heatsink has to be chosen according to application notes.
(*10) If remote sensing is not required, connect +S and -S to +V and -V respectively
(Refer to basical connection).
Auto restart
Positive
(H: ON, L: OFF)
/PV
(*12) For -40℃ to -20℃ operation, the regulation for output 2.5V, 3.3V, 5V, 12V and
15V is 40 mV.
Example: PAH75S48-5/P represent positive logic & OVP
shut-down
・All specifications are subject to change without notice.
B-150