Electrical Specifications
Electrical Characterisꢀcs (TA = 25° C unless otherwise noted)
SYMBOL
PARAMETER
MIN
TYP
MAX
UNITS
TEST CONDITIONS
Propagaꢀon Delay
OPL530
-
1.0
-
µs
EE = 0 or 1 mW/cm2, RL = 300 Ω to 5 V,
CL = 50 pF
EE = 0 or 1 mW/cm2, RL = 300 Ω to 5 V,
CL = 50 pF
tpEeT(+)
OPL530-OC
-
-
1.0
2.5
-
µs
µs
VCC = 5 V, TA = 25° C,
OPL550-OCA, OPL551-OC, OPL551-OCA
5
EE = 0 or 3 mW/cm2, RL = 8 TTL loads,
f = 10 kHz, DC = 50%
Propagaꢀon Delay
OPL530
EE = 0 or 1 mW/cm2, RL = 300 Ω to 5 V,
CL = 50 pF
-
-
3.0
2.5
-
µs
µs
OPL530-OC
tpEeT(-)
VCC = 5 V, TA = 25° C, EE = 0 or 3 mW/
OPL550-OCA, OPL551-OC, OPL551-OCA
5
cm2, RL = 360 Ω, f = 10 kHz, DC = 50%
Propagaꢀon Delay (Low-High/High-Low)
OPL560, OPL561
-
-
5
5
-
-
µs
µs
DC = 50%, RL = 10 TTL Loads
tPLH, tPHL
OPL561-OC
DC = 50%, RL = 300 Ω
Notes:
(1) RMA flux is recommended. Duraꢀon can be extended to 10 sec. max. when flow soldering. For OPL530, OPL530-OC and OPL536A a maxi-
mum of 20 grams force may be applied to leads while at soldering temperatures.
(2) Derate linearly 2.67 mW/° C above 70° C for OPL530, OPL530-OC, OPL531, OPL531-OCA, OPL535 and OPL536A. Derate linearly 2.5 mW/° C
above 25° C for all devices in the OPL550, OPL551, OPL560, OPL561, OPL562 and OPL563 series.
(3) Irradiance measurements are made with λi = 935 nm.
(4) This applies to OC versions only. For ICC on pull-up versions, add VCC/10 KΩ.
General Note
TT Electronics | OPTEK Technology
2900 E. Plano Pkwy, Plano, TX 75074 | Ph: +1 972 323 2200
TT Electronics reserves the right to make changes in product specificaꢀon without
noꢀce or liability. All informaꢀon is subject to TT Electronics’ own data and is
considered accurate at ꢀme of going to print.
www.ꢁelectronics.com | sensors@ꢁelectronics.com
Rev H 06/2022 Page 8
© TT electronics plc