OP07C
LINEAR INTEGRATED CIRCUIT
ABSOLUTE MAXIMUM RATING
(Over operating free-air temperature range unless otherwise specified)
PARAMETER
SYMBOL
VCC
VCC
RATINGS
0 ~ 22 (Note 2)
-22 ~ 0 (Note 2)
±30
UNIT
V
+
Supply Voltage
-
V
Differential Input Voltage (Note 3)
VID
VI
V
Input Voltage Range (Either Input) (Note 4)
Operating Virtual-Junction Temperature
±22
V
TJ
+150
°C
Notes: 1. Absolute maximum ratings are those values beyond which the device could be permanently damaged.
Absolute maximum ratings are stress ratings only and functional device operation is not implied.
2. All voltage values, unless otherwise noted, are with respect to the midpoint between VCC+ and VCC−.
3. Differential voltages are at IN+ with respect to IN−.
4. The magnitude of the input voltage must never exceed the magnitude of the supply voltage or 15V,
whichever is less.
RECOMMENDED OPERATING CONDITIONS
(Over operating free-air temperature range unless otherwise specified)
PARAMETER SYMBOL
VCC
VCC
RATINGS
3 ~ 18
UNIT
V
+
Supply Voltage
-
-3 ~ -18
-13 ~ 13
-40 ~ +85
V
Common-Mode Input Voltage (VCC±=±15 V)
Operating Free-Air Temperature
VIC
TA
V
°C
UNISONIC TECHNOLOGIES CO., LTD
4 of 6
QW-R105-062.B
www.unisonic.com.tw