MP4322 – 36V, 2A, LOW-IQ, SYNC BUCK CONVERTER WITH 42V LOAD DUMP
ELECTRICAL CHARACTERISTICS (continued)
VIN = 12V, VEN = 2V, TJ = -40°C to +125°C (11), typical values are at TJ = 25°C, unless otherwise noted.
Parameter
BOOT
Symbol
Condition
Min
Typ
Max
Units
BOOT - SW refresh rising
threshold
VBOOT_RISING
2.5
2.9
2.7
V
BOOT - SW refresh falling
threshold
VBOOT_FALLING
VBOOT_HYS
2.3
0.2
V
V
BOOT - SW refresh hysteresis
Enable (EN)
EN rising threshold
EN falling threshold
EN threshold hysteresis
Soft Start (SS) and VCC
Soft-start time
VEN_RISING
VEN_FALLING
VEN_HYS
0.97
0.8
1.02
0.85
170
1.07
0.9
V
V
mV
tSS
EN high to SS finishes
IVCC = 0
3
5
5
7
ms
V
VCC voltage
VCC
4.7
5.3
VCC regulation
IVCC = 30mA
VCC = 4V
1
%
VCC current limit
ILIMIT_VCC
50
70
mA
Power Good (PG)
VOUT rising
VOUT falling
VOUT falling
VOUT rising
93
104
94.5
105.5
93
96
107
PG rising threshold (VFB / VREF
)
PGVTH_RISING
91.5
105.5
94.5
108.5
%
PG falling threshold (VFB / VREF
)
PGVTH_FALLING
107
PG threshold hysteresis
PGVTH_HYS
VPG_LOW
tPG_R
1.5
(VFB / VREF
)
PG output voltage low
PG rising deglitch time
PG falling deglitch time
Protections
ISINK = 1mA
0.1
70
60
0.3
V
µs
µs
tPG_F
High-side (HS) peak current limit
Low-side (LS) valley current limit
ILIMIT_HS
ILIMIT_LS
Duty cycle = 30%
2.7
2
3.4
2.7
4.6
3.8
A
A
Zero-current detection (ZCD)
threshold
Thermal shutdown (12)
IZCD
-0.05
160
0.05
+0.15
185
A
TSD
175
20
°C
°C
Thermal shutdown hysteresis (12)
TSD_HYS
Notes:
11) Guaranteed by over-temperature correlation. Not tested in production.
12) Guaranteed by design and characterization. Not tested in production.