FREQUENCY INPUT LIMIT ALARM

MP1700-1-SX 数据手册

 浏览型号MP1700-1-SX的Datasheet PDF文件第2页浏览型号MP1700-1-SX的Datasheet PDF文件第3页浏览型号MP1700-1-SX的Datasheet PDF文件第4页 
Limit Alarms M-PAC  
MODEL  
FREQUENCY INPUT LIMIT ALARM  
MP1700-1723  
MODEL & SUFFIX CODE SELECTION  
50  
(1.97)  
MP17/❑  
MODEL  
80  
(3.15)  
INPUT TYPE  
SET  
1
SPAN  
ZERO  
7 : Frequency  
M•PAC  
LIMIT ALARM  
SET  
1
DEADBAND  
RELAY CONTACT OUTPUT  
0 : Single (Hi) trip, non-latching  
1 : Single (Hi) trip, latching  
2 : Dual (Hi/Lo) trip, non-latching  
SET  
2
DEADBAND  
132  
(5.20)  
SET  
2
mm (inch)  
SETPOINT CONTROL  
Functions & Features  
0 : Front-accessed three-turn screwdriver adjust.  
2 : Remote dial connections (total resistance 1k – 100k)  
3 : DC programmable (0 – 1V)  
INPUT  
1 : ON-OFF pulse  
(dry contact or open collector)  
2 : Voltage pulse  
• Accepting pulse input from turbine meters, posi-  
tive displacement flowmeters and other frequency  
generating devices • Providing relay contact  
closure(s) at a preset input level • Single, latching  
or dual setpoint • Failsafe operation available •  
Deadband adjustable from 1 to 100% • Indicator  
LED provided  
POWER INPUT  
Typical Applications  
F : 120V AC  
J : 240V AC  
• Annunciator • Various alarm applications  
R : 24V DC  
S : 12V DC  
OPTIONS  
GENERAL SPECIFICATIONS  
Construction: plug-in  
Connection: M3.5 screw terminals on base socket  
Housing material: flame-resistant resin (black)  
Isolation: input to output to power  
(non-isolated between I/O with Option V)  
Zero/span adjustments: ±5% (front)  
Setpoint adjustments: front accessed three-turn  
screwdriver, remote dial potentiometer  
or DC input  
H : Latching operation for dual trip (172X only);  
Reset at power off (5 seconds min.)  
R : Reversed relay sense  
T : Transmitter output (0 – 1V DC)  
V : Relay drive voltage output  
X : Lo-trip sense for single trip; Lo/Lo for dual trip  
Y : Hi/Hi-trip sense for dual trip (172X only)  
Deadband adjustments: front accessed single-turn  
screwdriver; 1 – 100%  
Front LEDs: red lights turn on at a tripped condition  
Low-end cutout: approx. 5%  
Power ON timer: relays de-energized for approx. 2  
seconds after power is turned on.  
ORDERING INFORMATION  
Specify code number and variables.  
Code number (e.g. MP1700-2-F/T/V)  
Frequency range (e.g. 0 – 500 Hz)  
P. 1 / 4  
ES-9806 Rev.5  

与MP1700-1-SX相关器件

型号 品牌 描述 获取价格 数据表
MP1700-1-SY MSYSTEM FREQUENCY INPUT LIMIT ALARM

获取价格

MP1700-2-FH MSYSTEM FREQUENCY INPUT LIMIT ALARM

获取价格

MP1700-2-FR MSYSTEM FREQUENCY INPUT LIMIT ALARM

获取价格

MP1700-2-FT MSYSTEM FREQUENCY INPUT LIMIT ALARM

获取价格

MP1700-2-FV MSYSTEM FREQUENCY INPUT LIMIT ALARM

获取价格

MP1700-2-FX MSYSTEM FREQUENCY INPUT LIMIT ALARM

获取价格