MJWI10 SERIES  
DC/DC CONVERTER 10W, High Power Density  
Total Power International, Inc.  
Test Setup  
Input Reflected-Ripple Current Test Setup  
Input reflected-ripple current is measured with a inductor Lin (4.7μH) and Cin (220μF, ESR < 1.0at 100 KHz) to simulate source impedance. Capacitor Cin, offsets  
possible battery impedance. Current ripple is measured at the input terminals of the module, measurement bandwidth is 0-500 KHz.  
To Oscilloscope  
+Vin  
+Out  
+
+
Lin  
DC / DC  
Converter  
Current  
Probe  
Load  
Battery  
Cin  
-Vin  
-Out  
Peak-to-Peak Output Noise Measurement Test  
Use a Cout 0.47μF ceramic capacitor. Scope measurement should be made by using a BNC socket, measurement bandwidth is 0-20 MHz. Position the load  
between 50 mm and 75 mm from the DC/DC Converter.  
Copper Strip  
Cout  
+Vin  
+Out  
Copper Strip  
Cout  
+Vin  
+Out  
Com.  
-Out  
Scope  
Scope  
Single Output  
DC / DC  
Converter  
Dual Output  
DC / DC  
Converter  
Resistive  
Load  
Resistive  
Load  
Scope  
Copper Strip  
Cout  
-Vin  
-Out  
Copper Strip  
-Vin  
Copper Strip  
Technical Notes  
Remote On/Off  
Positive logic remote on/off turns the module on during a logic high voltage on the remote on/off pin, and off during a logic low. To turn the power module on and off,  
the user must supply a switch to control the voltage between the on/off terminal and the -Vin terminal.  
The switch can be an open collector or equivalent. A logic low is 0V to 1V. A logic high is 2.5V to 50V. The maximum sink current at on/off terminal during a logic  
low is -500μA. The maximum allowable leakage current of the switch at on/off terminal (2.5 to 50V) is 500μA.  
Overcurrent Protection  
To provide protection in a fault (output overload) condition, the unit is equipped with internal current limiting circuitry and can endure current limiting for an unlimited  
duration. At the point of current-limit inception, the unit shifts from voltage control to current control. The unit operates normally once the output current is brought back  
into its specified range.  
Input Source Impedance  
The power module should be connected to a low ac-impedance input source. Highly inductive source impedances can affect the stability of the power module.  
In applications where power is supplied over long lines and output loading is high, it may be necessary to use a capacitor at the input to ensure startup.  
Capacitor mounted close to the power module helps ensure stability of the unit, it is recommended to use a good quality low Equivalent Series Resistance (ESR <  
1.0at 100 KHz) capacitor of a 6.8μF for the 24V and 48V devices.  
+
+Vin  
+Out  
+
DC / DC  
Converter  
DC Power  
Source  
Load  
Cin  
-
-Vin  
-Out  
Output Ripple Reduction  
A good quality low ESR capacitor placed as close as practicable across the load will give the best ripple and noise performance. To reduce output ripple, it is  
recommended to use 4.7μF capacitors at the output.  
+
+Vin  
-Vin  
+Out  
+
+Vin  
-Vin  
+Out  
Com.  
-Out  
Single Output  
DC / DC  
Converter  
Load  
Load  
Dual Output  
DC / DC  
Converter  
DC Power  
Source  
Cout  
Cout  
DC Power  
Source  
Cout  
Load  
-
-Out  
-
Maximum Capacitive Load  
The MJWI10 series has limitation of maximum connected capacitance at the output. The power module may be operated in current limiting mode during start-up,  
affecting the ramp-up and the startup time. The maximum capacitance can be found in the data sheet.  
Thermal Considerations  
Many conditions affect the thermal performance of the power module, such as orientation, airflow over the module and board spacing. To avoid exceeding the  
maximum temperature rating of the components inside the power module, the case temperature must be kept below 100. The derating curves are determined  
from measurements obtained in a test setup.  
Position of air velocity  
probe and thermocouple  
Air Flow  
50mm / 2in  
15mm / 0.6in  
DUT  
Total Power International, Inc  
Toll Free: 877-646-0900  
www.total-power.com  

与MJWI10相关器件

型号 品牌 描述 获取价格 数据表
MJWI10-24D05 TOTAL-POWER Shielded Metal Case with Isolated Baseplate

获取价格

MJWI10-24D05 MINMAX DC/DC CONVERTER 10W, High Power Density

获取价格

MJWI10-24D12 TOTAL-POWER Shielded Metal Case with Isolated Baseplate

获取价格

MJWI10-24D12 MINMAX DC/DC CONVERTER 10W, High Power Density

获取价格

MJWI10-24D15 MINMAX DC/DC CONVERTER 10W, High Power Density

获取价格

MJWI10-24D15 TOTAL-POWER Shielded Metal Case with Isolated Baseplate

获取价格